EATON – DILM17-32 – Electrical Switches – ICDC-040664 – New
Main Category: Electrical | Sub-Category: Switches | Status: New Original Components
EATON Part Number: DILM1732 | ICDC Internal Part Number: ICDC-040664
DILM17-32 Description:
DILM17-32(RDC24) – Contactor, 380 V 400 V 7.5 kW, 3 N/O, 2 NC, RDC 24: 24 – 27 V DC, DC operation, Screw terminals
DELIVERY PROGRAM
Product range
Contactors
Application
Contactors for Motors
Subrange
Complete devices up to 170 A
Utilization category
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-3/AC-3e: Normal AC induction motors: Starting, switching off while running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Connection technique
Notes
Also suitable for motors with efficiency class IE3.
Also tested according to AC-3e.
Rated operational current
AC-3
380 V 400 V [Ie] 18 A
AC-1
Conventional free air thermal current, 3 pole, 50 – 60 Hz
Open
at 40 °C [Ith =Ie] 40 A
AC-1
Conventional free air thermal current, 3 pole, 50 – 60 Hz
enclosed [Ith ] 32 A
AC-1
Conventional free air thermal current, 1 pole
open [Ith ] 88 A
AC-1
Conventional free air thermal current, 1 pole
enclosed [Ith ] 80 A
Max. rating for three-phase motors, 50 – 60 Hz
AC-3
220 V 230 V [P] 5 kW
AC-3
380 V 400 V [P] 7.5 kW
AC-3
660 V 690 V [P] 11 kW
AC-4
220 V 230 V [P] 2.5 kW
AC-4
380 V 400 V [P] 4.5 kW
AC-4
660 V 690 V [P] 6.5 kW
Contacts
N/O = Normally open
3 N/O
N/C = Normally closed
2 NC
Instructions
Contacts to EN 50 012.
integrated suppressor circuit in actuating electronics
with mirror contact.
Contact sequence
210S166
Actuating voltage
RDC 24: 24 – 27 V DC
Voltage AC/DC
DC operation
TECHNICAL DATA
General
Standards
IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanical
DC operated [Operations] 10 x 106
Operating frequency, mechanical
DC operated [Operations/h] 5000
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
Open
-25 – +60 °C
Ambient temperature
Enclosed
– 25 – 40 °C
Ambient temperature
Storage
– 40 – 80 °C Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock, 10 ms
Main contacts
N/O contact
10 g
Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock, 10 ms
Auxiliary contacts
N/O contact
7 g
Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock, 10 ms
Auxiliary contacts
N/C contact
5 g
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted
Half-sinusoidal shock, 10 ms
Main contacts
N/O contact
6.9 g
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted
Half-sinusoidal shock, 10 ms
Auxiliary contacts
N/O contact
5.3 g
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted
Half-sinusoidal shock, 10 ms
Auxiliary contacts
N/C contact
3.5 g
Degree of Protection
IP00
Protection against direct contact when actuated from front (EN 50274)
Finger and back-of-hand proof
Altitude
Max. 2000 m
Weight
DC operated
0.48 kg
Screw connector terminals
Terminal capacity main cable
Solid
1 x (0.75 – 16)
2 x (0.75 – 10) mm2
Screw connector terminals
Terminal capacity main cable
Flexible with ferrule
1 x (0.75 – 16)
2 x (0.75 – 10) mm2
Screw connector terminals
Terminal capacity main cable
Stranded
1 x 16 mm2
Screw connector terminals
Terminal capacity main cable
Solid or stranded
single 18 – 6, double 18 – 8 AWG
Screw connector terminals
Terminal capacity main cable
Stripping length
10 mm
Screw connector terminals
Terminal capacity main cable
Terminal screw
M5
Screw connector terminals
Terminal capacity main cable
Tightening torque
3.2 Nm
Screw connector terminals
Terminal capacity main cable
Tool
Pozidriv screwdriver
2 Size
Screw connector terminals
Terminal capacity main cable
Tool
Standard screwdriver
0.8 x 5.5
1 x 6 mm
Screw connector terminals
Terminal capacity control circuit cables
Solid
1 x (0.75 – 2.5)
2 x (0.75 – 2.5) mm2
Screw connector terminals
Terminal capacity control circuit cables
Flexible with ferrule
1 x (0.75 – 2.5)
2 x (0.75 – 2.5) mm2
Screw connector terminals
Terminal capacity control circuit cables
Solid or stranded
18 – 14 AWG
Screw connector terminals
Terminal capacity control circuit cables
Stripping length
10 mm
Screw connector terminals
Terminal capacity control circuit cables
Terminal screw
M3.5
Screw connector terminals
Terminal capacity control circuit cables
Tightening torque
1.2 Nm
Screw connector terminals
Terminal capacity control circuit cables
Tool
Pozidriv screwdriver
2 Size
Screw connector terminals
Terminal capacity control circuit cables
Tool
Standard screwdriver
0.8 x 5.5
1 x 6 mm
Main conducting paths
Rated impulse withstand voltage [Uimp] 8000 V AC
Overvoltage category/pollution degree
III/3
Rated insulation voltage [Ui] 690 V AC
Rated operational voltage [Ue] 690 V AC
Safe isolation to EN 61140
between coil and contacts
440 V AC
Safe isolation to EN 61140
between the contacts
440 V AC
Making capacity (p.f. to IEC/EN 60947) [Up to 690 V] 238 A
Breaking capacity
220 V 230 V
170 A
Breaking capacity
380 V 400 V
170 A
Breaking capacity
500 V
170 A
Breaking capacity
660 V 690 V
120 A
Short-circuit rating
Short-circuit protection maximum fuse
Type “2” coordination
400 V [gG/gL 500 V] 35 A
Short-circuit rating
Short-circuit protection maximum fuse
Type “2” coordination
690 V [gG/gL 690 V] 35 A
Short-circuit rating
Short-circuit protection maximum fuse
Type “1” coordination
400 V [gG/gL 500 V] 63 A
Short-circuit rating
Short-circuit protection maximum fuse
Type “1” coordination
690 V [gG/gL 690 V] 50 A
AC
AC-1
Rated operational current
Conventional free air thermal current, 3 pole, 50 – 60 Hz
Open
at 40 °C [Ith =Ie] 40 A
AC-1
Rated operational current
Conventional free air thermal current, 3 pole, 50 – 60 Hz
Open
at 50 °C [Ith =Ie] 38 A
AC-1
Rated operational current
Conventional free air thermal current, 3 pole, 50 – 60 Hz
Open
at 55 °C [Ith =Ie] 37 A
AC-1
Rated operational current
Conventional free air thermal current, 3 pole, 50 – 60 Hz
Open
at 60 °C [Ith =Ie] 35 A
AC-1
Rated operational current
Conventional free air thermal current, 3 pole, 50 – 60 Hz
enclosed [Ith ] 32 A
AC-1
Rated operational current
Conventional free air thermal current, 1 pole
open [Ith ] 88 A
AC-1
Rated operational current
Conventional free air thermal current, 1 pole
enclosed [Ith ] 80 A
AC-3
Rated operational current
Open, 3-pole: 50 – 60 Hz
Notes
At maximum permissible ambient temperature (open.)
Also tested according to AC-3e.
AC-3
Rated operational current
Open, 3-pole: 50 – 60 Hz
220 V 230 V [Ie] 18 A
AC-3
Rated operational current
Open, 3-pole: 50 – 60 Hz
240 V [Ie] 18 A
AC-3
Rated operational current
Open, 3-pole: 50 – 60 Hz
380 V 400 V [Ie] 18 A
AC-3
Rated operational current
Open, 3-pole: 50 – 60 Hz
415 V [Ie] 18 A
AC-3
Rated operational current
Open, 3-pole: 50 – 60 Hz
440V [Ie] 18 A
AC-3
Rated operational current
Open, 3-pole: 50 – 60 Hz
500 V [Ie] 18 A
AC-3
Rated operational current
Open, 3-pole: 50 – 60 Hz
660 V 690 V [Ie] 12 A
AC-3
Motor rating [P] 220 V 230 V [P] 5 kW
AC-3
Motor rating [P] 240V [P] 5.5 kW
AC-3
Motor rating [P] 380 V 400 V [P] 7.5 kW
AC-3
Motor rating [P] 415 V [P] 10 kW
AC-3
Motor rating [P] 440 V [P] 10.5 kW
AC-3
Motor rating [P] 500 V [P] 12 kW
AC-3
Motor rating [P] 660 V 690 V [P] 11 kW
AC-4
Open, 3-pole: 50 – 60 Hz
220 V 230 V [Ie ] 10 A
AC-4
Open, 3-pole: 50 – 60 Hz
240 V [Ie ] 10 A
AC-4
Open, 3-pole: 50 – 60 Hz
380 V 400 V [Ie ] 10 A
AC-4
Open, 3-pole: 50 – 60 Hz
415 V [Ie ] 10 A
AC-4
Open, 3-pole: 50 – 60 Hz
440 V [Ie ] 10 A
AC-4
Open, 3-pole: 50 – 60 Hz
500 V [Ie ] 10 A
AC-4
Open, 3-pole: 50 – 60 Hz
660 V 690 V [Ie ] 8 A
AC-4
Motor rating [P] 220 V 230 V [P] 2.5 kW
AC-4
Motor rating [P] 240 V [P] 3 kW
AC-4
Motor rating [P] 380 V 400 V [P] 4.5 kW
AC-4
Motor rating [P] 415 V [P] 5 kW
AC-4
Motor rating [P] 440 V [P] 5.5 kW
AC-4
Motor rating [P] 500 V [P] 6 kW
AC-4
Motor rating [P] 660 V 690 V [P] 6.5 kW
DC
Rated operational current, open
DC-1
60 V [Ie ] 35 A
Rated operational current, open
DC-1
110 V [Ie ] 35 A
Rated operational current, open
DC-1
220 V [Ie ] 35 A
Current heat loss
3 pole, at Ith (60°)
7.9 W
Current heat loss at Ie to AC-3/400 V
2.1 W
Impedance per pole
2.7 mΩ
Magnet systems
Voltage tolerance
DC operated [Pick-up] 0.7 – 1.2 x Uc
Voltage tolerance
Notes
RDC 24 (Umin 24 V DC/Umax 27 V DC)
Example: US = 0.7 x Umin – 1.2 x Umax / US = 0.7 x 24V – 1.2 x 27V DC
Voltage tolerance
DC operated [Drop-out] 0.15 – 0.6 x Uc
Voltage tolerance
Notes
at least smoothed two-phase bridge rectifier or three-phase rectifier
Power consumption of the coil in a cold state and 1.0 x US
DC operated [Pick-up] 12 W
Power consumption of the coil in a cold state and 1.0 x US
DC operated [Sealing] 0.9 W
Duty factor
100 % DF
Changeover time at 100 % US (recommended value)
Main contacts
DC operated
Closing delay
Closing delay
47 ms
Changeover time at 100 % US (recommended value)
Main contacts
DC operated
Opening delay
Opening delay
30 ms
Changeover time at 100 % US (recommended value)
Arcing time
10 ms
Lifespan, mechanical
Contact us to discover DILM17-32. ICDCSPARES.COM offers new or overhauled original components, ready in stock to be shipped via DHL Express! Call us!
Check our Electrical section to discover more about ICDC catalog: a large selection of industrial spare parts including Fuses, Electric Motors, Switches and Switches.
Are you looking for industrial Switches? ICDC offers online a wide selection of Switches of the most important OEMs like EATON, ABB and DANFOSS, besides EATON.
ICDC, Your Industrial One Stop Shop for Components!