EATON – DILM32-XHI22 – Electronic Modules – ICDC-040665 – New
Main Category: Electronics | Sub-Category: Modules | Status: New Original Components
EATON Part Number: DILM32XHI22 | ICDC Internal Part Number: ICDC-040665
DILM32-XHI22 Description:
DILM32-XHI22 – Auxiliary contact module, 4-pole, I ° = 16 A, 2 NO contact, 2 NC contact, Front fixing, Screw terminals, DILM7 – DILM38
277377
SUPPLY PROGRAM
accessories
Auxiliary contact modules
Description
with forcibly guided contacts
Function
for standard applications
Poly
4-pole
Types of connection
Screw terminals
Rated operational current
Conventional thermal current 1 pole
per day
a 60 °C [I°] 16 A
AC-15
220 V 230 V 240 V [ Ie ] 4 A
AC-15
380V 400V 415V [ Ie ] 4 A
Contact equipment
NA = norm. open
2 NO contact
NC = norm. Closed
2 NC contact
Mounting type
Front fixing
use with
DILM(C)7-10…
DILM(C)9-10…
DILM(C)12-10…
DILM(C)15-10…
DILM(C)17-10…
DILM(C)25-10…
DILM(C)32-10…
DILM38-10…
DILMP20…
DILMP32-10…
DILMP45-10…
DILL…
DILMF8-10…
DILMF11-10…
DILMF14-10…
DILMF17-10…
DILMF25-10…
DILMF32-10…
Execution
Auxiliary contact for surface mounting
Note
Forcibly guided contacts, according to IEC / EN 60947-5-1 Annex L, inside the auxiliary contact modules and for the integrated auxiliary contacts DILM 7 – DILM32
Auxiliary NC contact usable as mirror contact according to IEC / EN 60947-4-1 Attachment F (non-contact NC delayed)
TECHNICAL DATA
Generality
Compliance with standards
IEC / EN 60947, VDE 0660, UL, CSA
Lifespan of the appliance
with U e = 230 V, AC-15, 3 A [Operations] 1.3 x 106
Suitability for climates
Humid heat, constant, according to IEC 60068-2-78
Humid heat, cyclic according to IEC 60068-2-30
Room temperature
per day
-25 – +60 °C
Room temperature
in custody
– 25 – 40 °C
Room temperature
Ambient storage temperature
-40 – 80 °C
Shock resistance (IEC / EN 60068-2-27)
Sinusoidal shock 10 ms
Basic unit with auxiliary module
NA
7 g
Shock resistance (IEC / EN 60068-2-27)
Sinusoidal shock 10 ms
Basic unit with auxiliary module
NC
5 g
Degree of protection
IP20
Protection against accidental contact in case of frontal actuation (EN 50274)
Protection against finger and back of hand contact
Weight
0.048 kg
Connection sections
Screw terminals
Stiff
1 x (0,75-2,5)
2 x (0,75-2,5) mm2
Connection sections
Screw terminals
Flexible with ferrule
1 x (0,75-2,5)
2 x (0,75-2,5) mm2
Connection sections
Screw terminals
Single wire or stranded
18 – 14 AWG
Connection sections
Screw terminals
Pozidriv screwdriver
2 Size
Connection sections
Screw terminals
Flat-blade screwdriver
0.8 x 5.5
1 x 6 mm
Connection sections
Screw terminals
Max. Clamping force
1.2 Nm
Relay contacts
Forced guidance of the contact elements within an auxiliary contact module (in accordance with IEC 60947-5-1 Annex L)
Yup
NC contact (not delayed) suitable as mirror contact (in accordance with IEC / EN 60947-4-1 Appendix F)
DILM7 – DILM38
Rated impulse withstand voltage [U imp ] 6000 V AC
Overvoltage category / pollution degree
III/3
Rated insulation voltage [U i ] 690 V AC
Rated operational voltage [U e ] 500 V AC
Safe isolation according to EN 61140
between the coil and the contacts
400 V AC
Safe isolation according to EN 61140
between auxiliary contacts
400 V AC
Rated operational current
Conventional thermal current 1 pole
a 60 °C [I°] 16 A
Rated operational current
AC-15
220 V 230 V 240 V [ Ie ] 4 A
Rated operational current
AC-15
380V 400V 415V [ Ie ] 4 A
Rated operational current
AC-15
500 V [I e ] 1.5 A
Rated operational current
DC
Switch-on and switch-off conditions according to DC-13, constant L / R according to specification.
Rated operational current
DC
DC L/R ≦ 15 ms
Contacts in series:
1 [24 V] 10 A
Rated operational current
DC
DC L/R ≦ 15 ms
Contacts in series:
1 [60 V] 6 A
Rated operational current
DC
DC L/R ≦ 15 ms
Contacts in series:
1 [110 V] 3 A
Rated operational current
DC
DC L/R ≦ 15 ms
Contacts in series:
1 [220 V] 1 A
Rated operational current
DC
DC-13 (6xP)
24 V [I e ] 2.5 A
Rated operational current
DC
DC-13 (6xP)
60 V [I e ] 1 A
Rated operational current
DC
DC-13 (6xP)
110 V [I e ] 0.5 A
Rated operational current
DC
DC-13 (6xP)
220 V [I e ] 0.25 A
Rated operational current
Safety against false maneuvers [Frequency of failure] <10 -8 ,
Short circuit resistance without welding
Short circuit protection fuse max
500 V
10 A gG/gL
Ohmic loss at load with I th
Control in alternating current
2.6 W.
Ohmic loss at load with I th
Direct current control
2.6 W.
Ohmic loss at load with I th
Thermal dissipation for auxiliary circuit with I e (AC-15/230 V)
0.16 Watts
Power data approved
Auxiliary contacts
Pilot Duty
Control in alternating current
A600
Auxiliary contacts
Pilot Duty
Direct current control
P300
Auxiliary contacts
General Use
AC
600 V
Auxiliary contacts
General Use
AC
10 A
Auxiliary contacts
General Use
DC
250 V
Auxiliary contacts
General Use
DC
1 A
DESIGN VERIFICATIONS ACCORDING TO IEC / EN 61439
Technical data for design checks
Rated operational current for dissipation data [I n ] 4 A
Dissipation per pole, as a function of the current [P vid ] 0.16 Watts
Device dissipation, depending on the current [P vid ] 0 W.
Static dissipation, independent of the current [P vs ] 0 W.
Dissipation power [P ve ] 0 W.
Ambient service temperature min.
-25 °C
Ambient service temperature max.
+60 °C
IEC / EN 61439 design verifications
10.2 Suitability of materials and components
10.2.2 Corrosion resistance
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.3.1 Resistance of the enclosure to heat
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.3.2 Resistance of insulating materials to normal heat levels
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.3.3 Resistance of insulating materials to extraordinary heat levels
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.4 Resistance to UV radiation
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.5 Lifting
Not relevant as the whole electrical panel needs to be evaluated.
10.2 Suitability of materials and components
10.2.6 Impact test
Not relevant as the whole electrical panel needs to be evaluated.
10.2 Suitability of materials and components
10.2.7 Lettering
The requirements of the product standard are met.
10.3 Degree of protection of the enclosures
Not relevant as the whole electrical panel needs to be evaluated.
10.4 Airborne and superficial dispersion routes
The requirements of the product standard are met.
10.5 Protection against electric shock
Not relevant as the whole electrical panel needs to be evaluated.
10.6 Flush mounting of devices
Not relevant as the whole electrical panel needs to be evaluated.
10.7 Internal circuits and connections
It is the responsibility of the manufacturer of the electrical panel.
10.8 Connections for conductors introduced from outside
It is the responsibility of the manufacturer of the electrical panel.
10.9 Insulation characteristics
10.9.2 Mains frequency dielectric strength
It is the responsibility of the manufacturer of the electrical panel.
10.9 Insulation characteristics
10.9.3 Impulse withstand voltage
It is the responsibility of the manufacturer of the electrical panel.
10.9 Insulation characteristics
10.9.4 Verification of enclosures in insulating material
It is the responsibility of the manufacturer of the electrical panel.
10.10 Heating
The superheat calculation is the responsibility of the electrical panel builder. Eaton provides equipment dissipation data.
10.11 Resistance to short circuit
It is the responsibility of the manufacturer of the electrical panel. Observe the default values of the equipment.
10.12 EMC
It is the responsibility of the manufacturer of the electrical panel. Observe the default values of the equipment.
10.13 Mechanical function
For the device, the requirements are met if the information in the installation instructions (IL) is observed.
TECHNICAL DATA ACCORDING TO ETIM 8.0
low voltage electrical appliances (EG000017) / Auxiliary contacts (EC000041)
Technique Of Ar., Electr., Energy, Tecn. Switchgear, Network & Mains Process / Low Voltage Switching Technology / Component For Low Voltage Switching Technology / Auxiliary Switch Block ([email protected] [AKN342013])
number of reversing contacts
0
number of closing contacts
2
number of rest contacts
2
number of signal switches
0
rated operating current Ie for AC-15, 230 V
6 A
making the electrical connection
screw connection
Typology
pluggable
Mounting type
front fixing
lamp holder
without
APPROVALS
Product Standards
IEC/EN 60947-4-1
Contact us to discover DILM32-XHI22. ICDCSPARES.COM offers new or overhauled original components, ready in stock to be shipped via DHL Express! Call us!
Check our Electronics section to discover more about ICDC catalog: a large selection of industrial spare parts including Fuses, Electric Motors, Switches and Modules.
Are you looking for industrial Modules? ICDC offers online a wide selection of Modules of the most important OEMs like EATON, ABB and DANFOSS, besides EATON.
ICDC, Your Industrial One Stop Shop for Components!