EATON – FAZ-C32-2 – Electronic Modules – ICDC-040758 – New
Main Category: Electronics | Sub-Category: Modules | Status: New Original Components
EATON Part Number: FAZC322 | ICDC Internal Part Number: ICDC-040758
FAZ-C32-2 Description:
FAZ-C32 / 2 – Circuit breaker protector, 32 A, 2p, characteristic: C
SUPPLY PROGRAM
Basic function
line protection switch
Poly
2-pole
Characteristic intervention curve
C
Application
Equipment for industrial applications and high-end functional buildings
Rated current [I n ] 32 A
Rated opening capacity according to IEC / EN 60947-2 [I cu ] 15 kA
Assortment
DOES
TECHNICAL DATA
Electric
Compliance with standards
IEC/EN 60947-2
IEC/EN 60898
Rated operational voltage [U e ] [Ue] 240/415 V AC
Rated operational voltage [U e ] 60 (per pole) V DC
Rated voltage according to UL [U n ] 480Y/277 V CA
Rated opening capacity according to IEC / EN 60947-2 [I cu ] 15 kA
UL compliant breaking capacity
10 (UL1077) kA
Maximum operating voltage conforming to IEC / EN 60947-2
440 V AC
Rated breaking capacity equivalent to IEC / EN 60947-2 (maximum operating voltage) [I cu ] 10 kA
Rated short-circuit breaking capacity conforming to IEC / EN 60947-2 (maximum operating voltage) [I cs ] 7.5 kA
Rated voltage conforming to IEC / EN 60898-1. [U n ] 415 V AC
Rated breaking capacity conforming to IEC / EN 60898-1 [I cn ] 10 kA
Rated breaking capacity for short-circuit conforming to IEC / EN 60898-1 [I cs ] 7.5 kA
Switching power of use
7.5 kA
Characteristic curve
B, C, D, K, S, Z
Max. Fuse upstream
125 A gL/gG
Selectivity class
3
Duration
Duration [Maneuvers] > 10000
Sense of power
To taste
Mechanic
Shell mounting size
45 mm
Housing socket measurement
80 mm
Mounting width per pole
17.5 mm
Assembly
Omega guide IEC / EN 60715
Degree of protection
IP20, IP40 (incorporated)
Clamps above and below
Mouth clamps / liftable
Terminal protection
protected against contact with fingers / back of hand according to BGV A2
Connection sections
1 x 25 mm2
Connection sections
2 x 10 mm2
Busbar material thickness
0,8 – 2 mm
Mounting position
optional
DESIGN VERIFICATIONS ACCORDING TO IEC / EN 61439
Technical data for design checks
Rated operational current for dissipation data [I n ] 32 A
Dissipation per pole, as a function of the current [P vid ] 0 W.
Device dissipation, depending on the current [P vid ] 8.1 W.
Static dissipation, independent of the current [P vs ] 0 W.
Dissipation power [P ve ] 0 W.
Ambient service temperature min.
-40 °C
Ambient service temperature max.
+75 °C
linear for + 1 ° c causes a 0.5% decrease in the current load
IEC / EN 61439 design verifications
10.2 Suitability of materials and components
10.2.2 Corrosion resistance
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.3.1 Resistance of the enclosure to heat
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.3.2 Resistance of insulating materials to normal heat levels
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.3.3 Resistance of insulating materials to extraordinary heat levels
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.4 Resistance to UV radiation
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.5 Lifting
Not relevant as the whole electrical panel needs to be evaluated.
10.2 Suitability of materials and components
10.2.6 Impact test
Not relevant as the whole electrical panel needs to be evaluated.
10.2 Suitability of materials and components
10.2.7 Lettering
The requirements of the product standard are met.
10.3 Degree of protection of the enclosures
Not relevant as the whole electrical panel needs to be evaluated.
10.4 Airborne and superficial dispersion routes
The requirements of the product standard are met.
10.5 Protection against electric shock
Not relevant as the whole electrical panel needs to be evaluated.
10.6 Flush mounting of devices
Not relevant as the whole electrical panel needs to be evaluated.
10.7 Internal circuits and connections
It is the responsibility of the manufacturer of the electrical panel.
10.8 Connections for conductors introduced from outside
It is the responsibility of the manufacturer of the electrical panel.
10.9 Insulation characteristics
10.9.2 Mains frequency dielectric strength
It is the responsibility of the manufacturer of the electrical panel.
10.9 Insulation characteristics
10.9.3 Impulse withstand voltage
It is the responsibility of the manufacturer of the electrical panel.
10.9 Insulation characteristics
10.9.4 Verification of enclosures in insulating material
It is the responsibility of the manufacturer of the electrical panel.
10.10 Heating
The superheat calculation is the responsibility of the electrical panel builder. Eaton provides equipment dissipation data.
10.11 Resistance to short circuit
It is the responsibility of the manufacturer of the electrical panel. Observe the default values of the equipment.
10.12 EMC
It is the responsibility of the manufacturer of the electrical panel. Observe the default values of the equipment.
10.13 Mechanical function
For the device, the requirements are met if the information in the installation instructions (IL) is observed.
TECHNICAL DATA ACCORDING TO ETIM 8.0
circuit breakers, fuses, devices for series / wall installation (EG000020) / Magnetothermic switch (EC000042)
Technique Of Ar., Electr., Energy, Tecn. Of Comm., Network And Pipeline Proc. / Electrical Installations And Equipment Systems / Power Switch / Power Switch ([email protected] [AAB905014])
built-in depth
70.5 mm
intervention characteristic
C
number of poles (total)
2
number of protected poles
2
Nominal Current
32 A
Nominal tension
400 V
rated insulation voltage Ui
440 V
rated impulse voltage resistance Uimp
4 kV
rated breaking capacity Icn according to EN 60898 at 230 V
10 kA
type of supply voltage
AC
rated breaking capacity Icn according to EN 60898 at 400 V
10 kA
rated breaking capacity Icu according to IEC 60947-2 at 230 V
15 kA
rated breaking capacity Icu according to IEC 60947-2 at 400 V
15 kA
frequency
50 – 60 Hz
energy limitation class
3
recessed mounting
no
neutral conductor to connection
no
overvoltage category
3
degree of pollution
2
possible additional devices
Yes
Number of DIN modules
2
degree of protection (IP)
IP20
ambient temperature during operation
-25 – 75 °C
conductor section that can be connected to multi-wire
1 – 25 mm²
conductor section connectable single-wire
1 – 25 mm²
antideflagrant
no
APPROVALS
Product Standards
IEC/EN 60947-2