EATON – M22-K10 – Electromechanical Circuit Breakers | ICDC-041631
Main Category: Electromechanical | Sub-Category: Circuit Breakers | Status: New Original Components
Manufacturer: EATON | Part Number: M22K10 | ICDC Part Number: ICDC-041631
Lead Time: 2 Days to Shipping + DHL Express Transit Time
M22-K10 Description:
M22-K10 – Contact block, Screw terminals, Front fixing, 1 NO contact, 24 V 3 A, 220 V 230 V 240 V 6 A
EATON
216376 M22-K10
SUPPLY PROGRAM
Assortment
Accessories
Basic accessory function
Contact elements
accessories
Auxiliary contact
accessories
Normal auxiliary contacts, auxiliary signaling contacts
Standard / Approval
UL / CSA, IEC
Size
NZM1 / 2/3/4
Types of connection
Screw terminals
Type of fastening
Front fixing
Degree of protection
IP20
Connection to SmartWire-DT
no
use with
NZM1 (-4), 2 (-4), 3 (-4), 4 (-4)
PN1 (-4), 2 (-4), 3 (-4)
N (S) 1 (-4), 2 (-4), 3 (-4), 4 (-4)
Contact equipment
NA = norm. open
1 NO contact
Connection type
Single contact
Description of auxiliary contact for HIA release signaling
General “+” trip signaling in the event of tripping by voltage releases, thermal releases, short-circuit releases, and when using a differential protection module for the fault current.
Use with size NZM1, 2, 3 circuit breaker: an auxiliary trip contact can be clipped into the circuit breaker.
Use with size NZM4 circuit breaker: up to two auxiliary release contacts can be clipped into the circuit breaker.
Desired combinations of auxiliary contact types are possible.
Cannot be used in conjunction with PN … switch-disconnector
Marking on the circuit-breaker: HIA
Marking on the FI block: HIAFI.
Using the trip signaling auxiliary contact in the FI block, the opening contact functions as a closing contact and the closing contact as an opening contact.
Description of normal auxiliary contact HIN
Replicate the position of the main contacts Performs signaling and interlocking operations
Use with size NZM1 circuit breaker: a normal auxiliary contact can be clipped into the circuit breaker.
Use with size NZM2 circuit breaker: up to two normal auxiliary contacts can be clipped into the circuit breaker.
Use with size NZM3, 4 circuit breaker: up to three normal auxiliary contacts can be clipped into the circuit breaker.
Desired combinations of auxiliary contact types are possible.
Marking on the switch: HIN
In case of combination with remote control NZM-XR … the installation space on the right for normal auxiliary contacts HIN can only be equipped with single contacts.
Types of connection
Screw terminals
Note
The following applies to the packaging:
M22‐ (C) K…: package = 20 pieces
Note
Clips into the switch:
NZM1: A normal auxiliary contact
NZM2: up to 2 normal auxiliary contacts M22- (C) K …
NZM3: up to 3 normal auxiliary contacts M22- (C) K …
NZM4: up to 3 normal auxiliary contacts M22- (C) K …
Any combinations of auxiliary contact types are possible.
Marking on the switch: HIN
In the case of combinations with NZM-XR… remote control, some flush-mounted units with normal auxiliary contacts can only be equipped with single contacts.
NZM2: left-hand built-in unit with normal auxiliary contacts equipped with single contact only.
NZM3: all flush-mounted units with normal auxiliary contacts equipped with single contact only.
NZM4: right-hand built-in unit with normal auxiliary contacts equipped with single contact only.
TECHNICAL DATA
Generality
Compliance with standards
IEC 60947-5-1
Mechanical life [Operations]
> 5 x 10 6
Operating frequency [man / h]
≦ 3600
Actuation force
≦ 5 NET
Torque of the drive (screw terminals)
≦ 0.8 Nm
Degree of protection
IP20
Suitability for climates
Humid heat, constant, according to IEC 60068-2-78
Humid heat, cyclic according to IEC 60068-2-30
Room temperature
per day
-25 – +70 ° C
Shock resistance according to IEC 60068-2-27
Shock duration 11 ms, half wave
> 30 g
Connection sections
Stiff
0.75 – 2.5 mm 2
Connection sections
Flexible
0.5 – 2.5 mm 2
Connection sections
Flexible with ferrule
0.5 – 1.5 mm 2
Relay contacts
Rated impulse withstand voltage [U imp ]
6000 V AC
Rated insulation voltage [U i ]
500 V
Overvoltage category / pollution degree
III / 3
Safety against false maneuvers
at 24 V DC / 5 mA [H F ]
<10 - 7, <1 interruption out of 10 7 maneuvers Error frequency
Safety against false maneuvers
at 5 V DC / 1 mA [H F ]
<5 x 10 - 6 (dh 1 interruption on 5 x 106 operations) Error frequency
Max. Short-circuit protection device
without fuse
PKZM0-10 / FAZ-B6 / 1 Type
Max. Short-circuit protection device
Fuse [gG / gL]
10 A
Breaking power
Rated operational current [I e ]
AC-15
115 V [I e ]
6 A
Rated operational current [I e ]
AC-15
220 V 230 V 240 V [I e ]
6 A
Rated operational current [I e ]
AC-15
380 V 400 V 415 V [I e ]
4 A
Rated operational current [I e ]
AC-15
500 V [I e ]
2 A
Rated operational current [I e ]
DC-13
24 V [I e ]
3 A
Rated operational current [I e ]
DC-13
42 V [I e ]
1.7 A
Rated operational current [I e ]
DC-13
60 V [I e ]
1.2 A
Rated operational current [I e ]
DC-13
110 V [I e ]
0.6 A
Rated operational current [I e ]
DC-13
220 V [I e ]
0.3 A
Durability, electrical
AC-15
230 V / 0.5 A [Operations]
1.6 x 10 6
Durability, electrical
AC-15
230 V / 1.0 A [Operations]
1 x 10 6
Durability, electrical
AC-15
230 V / 3.0 A [Operations]
0.7 x 10 6
Durability, electrical
DC-13
12 V / 2.8 A [Operations]
1.2 x 10 6
Auxiliary contacts
Rated operational voltage [U e ]
Rated operational voltage [U e ]
500 V AC
Rated operational voltage [U e ]
Rated operational voltage max. [EU]
220 V DC
Conventional thermal current in free air [I t h =Ie]
4 A
Rated operational current [I e ]
Different rated operational currents when used as an auxiliary contact for the NZM circuit breaker
M22- (C) K10 (01) M22-CK11 (02) (20) XHIV
bei AC = 50/60 Hz
Bemessungsbetriebsstrom
AC-15 115 V Ie TO 4 4 4
230 V Ie TO 4 4 4
400 V Ie TO 2 - 2
500 V Ie TO 1 - 1
DC-13 24 V Ie TO 3 3 3
42 V Ie TO 1.7 1 1.5
60 V Ie TO 1.2 0.8 0.8
110 V Ie TO 0.6 0.5 0.5
220 V Ie TO 0.3 0.2 0.2
Short circuit protection
Max fuse
10 A dd / gL
Short circuit protection
circuit breaker max.
FAZ-B6 / B1 A
Switching times
HIV lead time with respect to main contacts at insertion and disconnection
(switching times with manual control):
NZM1, PN1, N (S) 1: approx. 20 ms
NZM2, PN2, N (S) 2: approx. 20 ms
NZM3, PN3, N (S) 3: approx. 20 ms
NZM4, N (S) 4: approx. 90 ms, HIV does not anticipate switching off .
Connection sections
Rigid / flexible, with tip
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm 2
UL / CSA
Rated operational current [I e ]
5 A - 600 V AC
1 A - 250 V DC A
Other technical data (browsable catalog)
Maximum equipment and location of interior accessories
DESIGN VERIFICATIONS ACCORDING TO IEC / EN 61439
Technical data for design checks
Rated operational current for dissipation data [I n ]
6 A
Dissipation per pole, as a function of the current [P vid ]
0.11 W
Device dissipation, depending on the current [P vid ]
0 W
Static dissipation, independent of the current [P vs ]
0 W
Dissipation power [P ve ]
0 W
Ambient service temperature min.
-25 ° C
Ambient service temperature max.
+70 ° C
IEC / EN 61439 design verifications
10.2 Suitability of materials and components
10.2.2 Corrosion resistance
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.3.1 Resistance of the enclosure to heat
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.3.2 Resistance of insulating materials to normal heat levels
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.3.3 Resistance of insulating materials to extraordinary heat levels
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.4 Resistance to UV radiation
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.5 Lifting
Not relevant as the whole electrical panel needs to be evaluated.
10.2 Suitability of materials and components
10.2.6 Impact test
Not relevant as the whole electrical panel needs to be evaluated.
10.2 Suitability of materials and components
10.2.7 Lettering
The requirements of the product standard are met.
10.3 Degree of protection of the enclosures
Not relevant as the whole electrical panel needs to be evaluated.
10.4 Air and surface dispersion routes
The requirements of the product standard are met.
10.5 Protection against electric shock
Not relevant as the whole electrical panel needs to be evaluated.
10.6 Flush mounting of devices
Not relevant as the whole electrical panel needs to be evaluated.
10.7 Internal circuits and connections
It is the responsibility of the manufacturer of the electrical panel.
10.8 Connections for conductors introduced from outside
It is the responsibility of the manufacturer of the electrical panel.
10.9 Insulation characteristics
10.9.2 Dielectric strength at mains frequency
It is the responsibility of the manufacturer of the electrical panel.
10.9 Insulation characteristics
10.9.3 Impulse withstand voltage
It is the responsibility of the manufacturer of the electrical panel.
10.9 Insulation characteristics
10.9.4 Verification of enclosures in insulating material
It is the responsibility of the manufacturer of the electrical panel.
10.10 Heating
The superheat calculation is the responsibility of the electrical panel builder. Eaton provides equipment dissipation data.
10.11 Resistance to short circuit
It is the responsibility of the manufacturer of the electrical panel. Observe the default values of the equipment.
10.12 EMC
It is the responsibility of the manufacturer of the electrical panel. Observe the default values of the equipment.
10.13 Mechanical function
For the device, the requirements are met if the information in the installation instructions (IL) is observed.
TECHNICAL DATA ACCORDING TO ETIM 8.0
low voltage electrical appliances (EG000017) / Auxiliary contacts (EC000041)
Technique Of Ar., Electr., Energy, Tecn. Switchgear, Network & Mains Process / Low Voltage Switching Technology / Component For Low Voltage Switching Technology / Auxiliary Switch Block ([email protected] [AKN342013])
number of reversing contacts
0
number of closing contacts
1
number of rest contacts
0
number of signal switches
0
rated operating current Ie for AC-15, 230 V
6 A
making the electrical connection
screw connection
Typology
insertable and integrable
Mounting type
front fixing
lamp holder
without
APPROVALS
Product Standards
IEC / EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking
UL File No.
E29184
UL Category Control No.
NKCR
CSA File No.
012528
CSA Class No.
3211-03
North America Certification
UL listed, CSA certified
Degree of Protection
UL / CSA Type: -
Contact us to discover more about the Circuit Breakers by EATON code M22-K10
Are you looking for EATON industrial components?
ICDCSPARES.COM offers new and overhauled original components, ready in stock to be shipped via DHL Express! Call us!
Check our Circuit Breakers section to discover more about ICDC catalog: a wide selection of industrial spare parts, including Compressors, Flow Control Valves, UPS and Rotary Joints, besides Circuit Breakers. ICDC offers online a wide selection of Electromechanical industrial components of the most important OEMs like EUGEN SEITZ, BECKHOFF, SKF, COPELAND and ALFA LAVAL beyond EATON.
ICDC,
Your Industrial One Stop Shop for Components!