EATON – TM-2-8292-E-SVB – Electrical Switches – ICDC-040994 – New
Main Category: Electrical | Sub-Category: Switches | Status: New Original Components
EATON Part Number: TM28292ESVB | ICDC Internal Part Number: ICDC-040994
TM-2-8292-E-SVB Description:
TM-2-8292/E/SVB 045484 EATON ELECTRIC
Control circuit switches, Emergency-Stop function, Contacts: 3, 10 A
Delivery program
Product range
Control switches
Part group reference
TM
Basic function
Control circuit switches
Stop Function
Emergency switching off function
With red rotary handle and yellow locking ring
Notes
up to 250 V AC per contact
Contacts
3
Locking facility
Lockable in the 0 (Off) position
Degree of Protection
Front IP65
Design
flush mounting
000Z427
Contact sequence
115S009-2
Switching angle
90 °
Design number
8292
Front plate no.
115N005
Motor rating AC-23A, 50 – 60 Hz [P] 400 V [P] 3 kW
Rated uninterrupted current [Iu] 10 A
Note on rated uninterrupted current !u
Rated uninterrupted current I
u
is specified for max. cross-section.
Number of contact units
2 contact unit(s)
Technical data
General
Standards
IEC/EN 60947, VDE 0660, CSA, UL
Control switch as per IEC/EN 60947-5-1
Auxiliary switch as per IEC/EN 60947-5-1
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
Open
-25 – +50 °C
Overvoltage category/pollution degree
III/3
Rated impulse withstand voltage [Uimp] 4000 V AC
Mounting position
As required
Contacts
Electrical characteristics
Rated operational voltage [Ue] 500 V AC
Electrical characteristics
Rated uninterrupted current [Iu] 10 A
Electrical characteristics
Note on rated uninterrupted current !u
Rated uninterrupted current I
u
is specified for max. cross-section.
Short-circuit rating
Fuse
10 A gG/gL
Switching capacity
Safe isolation to EN 61140
Current heat loss per contact at Ie
0.15 W
Safe isolation to EN 61140
Current heat loss per auxiliary circuit at Ie(AC-15/230 V)
0.15 CO
Lifespan, mechanical [Operations] > 1 x 10
6
Maximum operating frequency [Operations/h] 1200
AC
AC-23A
Motor rating AC-23A, 50 – 60 Hz [P] 400 V 415 V [P] 3 kW
Control circuit reliability at 24 V DC, 10 mA [Fault probability] < 10
-5
,< 1 failure in 100,000 switching operations H
F
Terminal capacities
Solid or stranded
1 x 1,5
2 x 1,5 mm
2
Flexible with ferrules to DIN 46228
1 x 1.0
2 x 1.0 mm
2
Flexible
1 x 1.5
2 x 1.5 mm
2
Terminal screw
M2.5
Tightening torque for terminal screw
0.4 Nm
Rating data for approved types
Contacts
Rated operational voltage [Ue] 300 V AC
Contacts
Rated uninterrupted current max.
Main conducting paths
General use
10 A
Contacts
Rated uninterrupted current max.
Auxiliary contacts
General Use [IU] 10 A
Contacts
Rated uninterrupted current max.
Auxiliary contacts
Pilot Duty
A 300
Switching capacity
Maximum motor rating
Single-phase
120 V AC
0.33 HP
Switching capacity
Maximum motor rating
Single-phase
240 V AC
0.75 HP
Switching capacity
Maximum motor rating
Single-phase
277 V AC
0.75 HP
Switching capacity
Maximum motor rating
Three-phase
120 V AC
0.75 HP
Switching capacity
Maximum motor rating
Three-phase
240 V AC
1 HP
Terminal capacity
Solid or flexible conductor with ferrule
14 AWG
Terminal capacity
Terminal screw
M2.5
Terminal capacity
Tightening torque
3.5 lb-in
Design verification as per IEC/EN 61439
Technical data for design verification
Rated operational current for specified heat dissipation [In] 10 A
Heat dissipation per pole, current-dependent [Pvid] 0.15 W
Equipment heat dissipation, current-dependent [Pvid] 0 W
Static heat dissipation, non-current-dependent [Pvs] 0 W
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+50 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts
10.2.2 Corrosion resistance
Meets the product standard’s requirements.
10.2 Strength of materials and parts
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard’s requirements.
10.2 Strength of materials and parts
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard’s requirements.
10.2 Strength of materials and parts
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard’s requirements.
10.2 Strength of materials and parts
10.2.4 Resistance to ultra-violet (UV) radiation
UV resistance only in connection with protective shield.
10.2 Strength of materials and parts
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
10.2.7 Inscriptions
Meets the product standard’s requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard’s requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder’s responsibility.
10.8 Connections for external conductors
Is the panel builder’s responsibility.
10.9 Insulation properties
10.9.2 Power-frequency electric strength
Is the panel builder’s responsibility.
10.9 Insulation properties
10.9.3 Impulse withstand voltage
Is the panel builder’s responsibility.
10.9 Insulation properties
10.9.4 Testing of enclosures made of insulating material
Is the panel builder’s responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 7.0
Low-voltage industrial components (EG000017) / Switch disconnector (EC000216)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Switch disconnector ([email protected] [AKF060013])
Version as main switch
Yes
Version as maintenance-/service switch
Yes
Version as safety switch
No
Version as emergency stop installation
Yes
Version as reversing switch
No
Number of switches
1
Max. rated operation voltage Ue AC
500 V
Rated operating voltage
500 – 500 V
Rated permanent current Iu
10 A
Rated permanent current at AC-23, 400 V
A
Rated permanent current at AC-21, 400 V
0 A
Rated operation power at AC-3, 400 V
0 kW
Rated short-time withstand current lcw
0 kA
Rated operation power at AC-23, 400 V
0 kW
Switching power at 400 V
0 kW
Conditioned rated short-circuit current Iq
0 kA
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Motor drive optional
No
Motor drive integrated
No
Voltage release optional
No
Device construction
Built-in device fixed built-in technique
Suitable for ground mounting
No
Suitable for front mounting 4-hole
Yes
Suitable for front mounting centre
No
Suitable for distribution board installation
No
Suitable for intermediate mounting
No
Colour control element
Red
Type of control element
Door coupling rotary drive
Interlockable
Yes
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP65
Degree of protection (NEMA)
Other
Approvals
Product Standards
UL 508
Contact us to discover TM-2-8292-E-SVB. ICDCSPARES.COM offers new or overhauled original components, ready in stock to be shipped via DHL Express! Call us!
Check our Electrical section to discover more about ICDC catalog: a large selection of industrial spare parts including Fuses, Electric Motors, Switches and Switches.
Are you looking for industrial Switches? ICDC offers online a wide selection of Switches of the most important OEMs like EATON, ABB and DANFOSS, besides EATON.
ICDC, Your Industrial One Stop Shop for Components!