PHOENIX – 1569391 – Electrical Connectors-Contactors – ICDC-040126 – New
Main Category: Electrical | Sub-Category: Connectors-Contactors | Status: New Original Components
PHOENIX Part Number: 1569391 | ICDC Internal Part Number: ICDC-040126
1569391 Description:
Bus system cable – SAC-4P-M12MSD / 2,0-931
1569391 PHOENIX
Bus system cable, Ethernet CAT5 (100 Mbps), 4-pin, PUR halogen-free, sea blue RAL 5021, shielded, Plug straight M12, coding: D, on free cable end, cable length: 2 m
Product type Pre-assembled data cable
No. poles 4
Application Standard
Number of cable outlets 1
Coding D – Data
Features of insulation
Overvoltage category II
Degree of pollution 3
Bus system Ethernet
Signal type / category Ethernet CAT5 (IEC 11801), 100 MBit / s
Status reporting No
Status indication available No
Mass resistivity ≤ 5 mΩ
Insulation resistance ≥ 100 MΩ
Rated voltage U N 48 V AC
60 V DC
Rated current I N 4 A (Male / female connector according to IEC 61076-2-101, observe the technical data of the cable)
Transmission medium Copper
Handles color black
Combustion class according to UL 94 V0
Handle material TPU, hardly flammable, self-extinguishing
Contact material CuSn
Contact surface material Ni / Au
Contact insert material PA 6.6
Screw material Zinc die-cast, nickel-plated
Maneuver cycles ≥ 100
Connection 1
Head structure Male
Head cable outlet right
Head thread type M12
Coding D.
Connection 2
Head structure free conductor end
Cable length 2 m
Line weight 42 kg / km
UL AWM Style 20963 (80 ° C / 30 V)
No. poles 4
Shielded Yes
Cable type Flexible Ethernet CAT5, 2-pair [93E]Runtime 5.3 ns / m
Line signal conductor structure 7x 0.16 mm
AWG signal line 26
Conductor cross section 2x 2x 0.14 mm²
Wire diameter with insulating sheath 0.98 mm
Conductor outer diameter 6.4 mm ± 0.2 mm
Outer sheath, material EVEN THOUGH
Outer sheath, color sea blue RAL 5021
Conductor material Bare Cu wire
Material, wire insulation Expanded PE
Single conductor, color white / orange-orange, white / green-green
Wall thickness outer sheath 1.2 mm
Twisting in pairs 2 conductors in pairs
Whole stranding 2 paisa with 2 fillers towards the core
Optical shield cover 70%
Insulation resistance ≥ 500 MΩ * km
Coupling resistance ≤ 100.00 mΩ / m (with 10 MHz)
Resistance of the twisted pair ≤ 290.00 Ω / km
Characteristic impedance 100 Ω ± 5 Ω (with 100 MHz)
Line capacity ca. 45 nF / km (at 1 kHz)
Rated cable voltage ≤ 100 V (Peak value, not for high currents)
Thread / thread test tension 700 V (50 Hz, 1 min.)
Test wire / shield voltage 700 V (50 Hz, 1 min.)
Permissible current load of the cable 2 A (according to DIN VDE 0891-1)
Minimum bending radius, fixed 4 x D
Minimum bend radius, flexible 8 x D
Tensile strength ≤ 80 N
Paradiaphonic attenuation (NEXT) 65.3 dB (with 1 MHz)
56.3 dB (with 4 MHz)
50.3 dB (with 10 MHz)
47.2 dB (with 16 MHz)
45.8 dB (with 20 MHz)
42.9 dB (at 31.25 MHz)
38.4 dB (with 62.5 MHz)
35.3 dB (with 100 MHz)
Power-Sum Paraphone Attenuation (PSNEXT) 62.3 dB (with 1 MHz)
53.3 dB (with 4 MHz)
47.3 dB (with 10 MHz)
44.2 dB (with 16 MHz)
42.8 dB (with 20 MHz)
39.9 dB (at 31.25 MHz)
35.4 dB (with 62.5 MHz)
32.3 dB (with 100 MHz)
Return Attenuation (RL) 23 dB (with 4 MHz)
24.1 dB (with 8 MHz)
25 dB (with 10 MHz)
25 dB (with 16 MHz)
25 dB (with 20 MHz)
23.6 dB (at 31.25 MHz)
21.5 dB (with 62.5 MHz)
20.1 dB (with 100 MHz)
Shield attenuation 3.2 dB (with 1 MHz)
6 dB (with 4 MHz)
9.5 dB (with 10 MHz)
12.1 dB (with 16 MHz)
13.6 dB (with 20 MHz)
17.1 dB (at 31.25 MHz)
24.8 dB (with 62.5 MHz)
32 dB (with 100 MHz)
Absence of halogens according to IEC 60754-1
Resistance to flame according to IEC 60332-1-2
according to UL VW1
Resistance to oil according to EN 60811-2-1
Ambient temperature (operation) -40 ° C … 80 ° C (cables, fixed installation)
-20 ° C … 80 ° C (Cables, mobile laying)
Ambient temperature (installation) -20 ° C … 80 ° C
Cable structure
Signal type / category Ethernet CAT5 (IEC 11801), 100 MBit / s
Environmental conditions
Ambient temperature (operation) -20 ° C … 70 ° C (cables, fixed installation)
0 ° C … 50 ° C (Cables, mobile laying)
Degree of protection IP65
IP67
Ambient temperature (operation) -25 ° C … 90 ° C (female connector / connector)
-20 ° C … 70 ° C (cables, fixed installation)
0 ° C … 50 ° C (Cables, mobile laying)
Contact us to discover 1569391. ICDCSPARES.COM offers new or overhauled original components, ready in stock to be shipped via DHL Express! Call us!
Check our Electrical section to discover more about ICDC catalog: a large selection of industrial spare parts including Fuses, Electric Motors, Switches and Connectors-Contactors.
Are you looking for industrial Connectors-Contactors?
ICDC offers online a wide selection of Connectors-Contactors of the most important OEMs like EATON, ABB and DANFOSS, besides PHOENIX.ICDC, Your Industrial One Stop Shop for Components!