SCHNEIDER – XALK178F – Electrical Buttons – ICDC-041037 – New
Main Category: Electrical | Sub-Category: Buttons | Status: New Original Components
SCHNEIDER ELECTRIC Part Number: XALK178F | ICDC Internal Part Number: ICDC-041037
XALK178F Description:
Presentation
Product range
Harmony XALK
Type of product or component
Complete control station
Device name
XALK
product application
For control and signaling unit XB5 Ø 22 mm
Button panel application
Emergency stop function Emergency
stop function
Base color of the box
Light gray (RAL 7035)
Cover color
Yellow (RAL 1021)
Material
Polycarbonate
Operator type
1 mushroom button
Operators description
Red without marking 2 NC
reset
Turn to unlock
Control station composition
1 mushroom head button Ø 40 mm, red 2 NC unmarked markings
Contact operation
Slow opening
Technical features
Cable entry
1 knockout entry for 0 … 14 mm cable gland
2 knockout entries for Pg 13 and ISO M20 0 … 12 mm cable gland
product weight
0.194 kg
Resistance to high pressure washing
7000000 Pa at 55 ° C, distance: 0.1 m
Positive opening
With conforming to EN / IEC 60947-5-1 appendix K
Operation stroke
1.5 mm (NC with electrical status change)
4.3 mm (total stroke)
Operating force
44 No.
Mechanical durability
300000 cycles
Connections – terminals
Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN / IEC 60947-1 Screw clamp
terminals,> = 1 x 0.22 mm² without cable end conforming to EN / IEC 60947-1
tightening torque
0.8 … 1.2 Nm conforming to EN / IEC 60947-1
Head shape (screw)
Phillips head compatible with Philips no 1 screwdriver Phillips
head compatible with pozidriv No 1 screwdriver Slotted
compatible with flat Ø 4 mm screwdriver Slotted
compatible with flat Ø 5.5 mm screwdriver
Contact material
Silver alloy (Ag / Ni)
Short circuit protection
10 A cartridge fuse type gG conforming to EN / IEC 60947-5-1
Conventional thermal current in air [Ith] 10 A conforming to EN / IEC 60947-5-1
Rated insulation voltage [Ui] 600 V (pollution degree 3) conforming to EN / IEC 60947-1
Rated impulse withstand voltage [Uimp] 6 kV conforming to EN / IEC 60947-1
Rated operational current [Ie] 3 A at 240 V, AC-15, A600 conforming to EN / IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN / IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN / IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN / IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN / IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN / IEC 60947-5-1
Electrical durability
1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc / h, load factor: 0.5 conforming to EN / IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc / h, load factor: 0.5 conforming to EN / IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cycles / h, load factor: 0.5 conforming to EN / IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc / h, load factor : 0.5 conforming to EN / IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc / h, load factor: 0.5 conforming to EN / IEC 60947-5-1 appendix C
Electrical reliability
Λ <10exp (-6) at 5 V, 1 mA conforming to EN / IEC 60947-5-4
Λ <10exp (-8) at 17 V, 5 mA conforming to EN / IEC 60947-5-4
Environment
Protective treatment
TH
Storage temperature
-40 … 70 ° C
Operating ambient temperature
-40 … 70 ° C
overvoltage category
Class II conforming to IEC 60536
IP protection degree
IP66 conforming to IEC 60529
IP67
IP69
IP69K
NEMA degree of protection
NEMA 13
NEMA 4X
IK degree of protection
IK03 conforming to EN 50102
Reference standards
EN / IEC 60204-1
JIS C 4520
EN / IEC 60947-5-1
IEC 60364-5-53
EN / ISO 13850
CSA C22.2 No 14
UL 508
EN / IEC 60947-5-5
EN / IEC 60947-5- 4
EN / IEC 60947-1
vibration resistance
5 gn (f = 12 … 500 Hz) conforming to IEC 60068-2-6
impact resistance
30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Packaging
Packaging unit type 1
PCE
No. of units in pkg.
1
Packing weight (Kg)
168.0 g
Packaging height 1
9.7 cm
Packaging width 1
7 cm
Packaging length 1
7 cm
Packaging unit type 2
P06
Packing unit number 2
320
Packing weight 2
67.964 kg
Packaging height 2
77 cm
Packaging width 2
80 cm
Packaging length 2
60 cm
Packaging unit type 3
S03
Packing unit number 3
40
Packing weight 3
7.202 kg
Packaging height 3
30 cm
Packaging width 3
30 cm
Packaging length 3
40 cm
Contact us to discover XALK178F. ICDCSPARES.COM offers new or overhauled original components, ready in stock to be shipped via DHL Express! Call us!
Check our Electrical section to discover more about ICDC catalog: a large selection of industrial spare parts including Fuses, Electric Motors, Switches and Buttons.
Are you looking for industrial Buttons? ICDC offers online a wide selection of Buttons of the most important OEMs like EATON, ABB and DANFOSS, besides SCHNEIDER ELECTRIC.
ICDC, Your Industrial One Stop Shop for Components!