ABB – AF09-30-10-11 – Electromechanical Relays – ICDC-040560 – New
Main Category: Electromechanical | Sub-Category: Relays | Status: New Original Components
ABB Part Number: AF09301011 | ICDC Internal Part Number: ICDC-040560
AF09-30-10-11 Description:
AF09-30-10-11
General Information
Extended Product Type:AF09-30-10-11
Product ID:1SBL137001R1110
EAN:3471523110014
Catalog Description:AF09-30-10-11 24-60V50/60HZ 20-60VDC Contactor
Long Description:The AF09-30-10-11 is a 3 pole – 690 V IEC or 600 UL contactor with 1 built-in auxiliary contact and screw terminals, controlling motors up to 4 kW / 400 V AC (AC-3) or 5 hp / 480 V UL and switching power circuits up to 25 A (AC-1) or 25 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Ordering
Minimum Order Quantity:1 piece
Customs Tariff Number:85364900
Popular Downloads
Instructions and Manuals:1SBC101027M6801
CAD Dimensional Drawing:2CDC001079B0201
Dimensions
Product Net Width:45 mm
Product Net Depth / Length:77 mm
Product Net Height:86 mm
Product Net Weight:0.27 kg
Technical
Number of Main Contacts NO:3
Number of Main Contacts NC:0
Number of Auxiliary Contacts NO:1
Number of Auxiliary Contacts NC:0
Standards:IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
Rated Operational Voltage:Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f):Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors q = 40 °C 35 A
acc. to IEC 60947-5-1, q = 40 °C 16 A
Rated Operational Current AC-1 (Ie):(690 V) 40 °C 25 A
(690 V) 60 °C 25 A
(690 V) 70 °C 22 A
Rated Operational Current AC-3 (Ie):(415 V) 60 °C 9 A
(440 V) 60 °C 9 A
(500 V) 60 °C 9.5 A
(690 V) 60 °C 7 A
(380 / 400 V) 60 °C 9 A
(220 / 230 / 240 V) 60 °C 9 A
Rated Operational Current AC-3e (Ie):(415 V) 60 °C 9 A
(440 V) 60 °C 9 A
(500 V) 60 °C 9.5 A
(690 V) 60 °C 7 A
(380 / 400 V) 60 °C 9 A
(220 / 230 / 240 V) 60 °C 9 A
Rated Operational Power AC-3 (Pe):(400 V) 4 kW
(415 V) 4 kW
(440 V) 4 kW
(500 V) 5.5 kW
(690 V) 5.5 kW
(380 / 400 V) 4 kW
(220 / 230 / 240 V) 2.2 kW
Rated Operational Power AC-3e (Pe):(415 V) 4 kW
(440 V) 4 kW
(500 V) 5.5 kW
(690 V) 5.5 kW
(380 / 400 V) 4 kW
(220 / 230 / 240 V) 2.2 kW
Rated Operational Current AC-15 (Ie):(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw):at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Maximum Electrical Switching Frequency:(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 300 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie):(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
Rated Insulation Voltage (Ui):acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):6 kV
Maximum Mechanical Switching Frequency:3600 cycles per hour
Rated Control Circuit Voltage (Uc):50 Hz 24 … 60 V
60 Hz 24 … 60 V
DC Operation 20 … 60 V
Operate Time:Between Coil De-energization and NC Contact Closing 13 … 98 ms
Between Coil De-energization and NO Contact Opening 11 … 95 ms
Between Coil Energization and NC Contact Opening 38 … 90 ms
Between Coil Energization and NO Contact Closing 40 … 95 ms
Mounting on DIN Rail:TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied):2 x M4 screws placed diagonally
Connecting Capacity Main Circuit:Flexible with Ferrule 1/2x 0.75 … 6 mm²
Flexible with Insulated Ferrule 1x 0.75 … 4 mm²
Flexible with Insulated Ferrule 2x 0.75 … 2.5 mm²
Rigid 1/2x 1 … 6 mm²
Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm²
Rigid 1/2x 1 … 2.5 mm²
Connecting Capacity Control Circuit:Flexible with Ferrule 1/2x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm²
Rigid 1/2x 1 … 2.5 mm²
Wire Stripping Length:Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 10 mm
Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal Type:Screw Terminals
Technical UL/CSA
NEMA Size:00
Continuous Current Rating NEMA:9 A
Horsepower Rating NEMA:(115 V AC) Single Phase 1/3 Hp
(200 V AC) Three Phase 1-1/2 Hp
(230 V AC) Single Phase 1 Hp
(230 V AC) Three Phase 1-1/2 Hp
(460 V AC) Three Phase 2 Hp
(575 V AC) Three Phase 2 Hp
General Use Rating UL/CSA:(600 V AC) 25 A
Horsepower Rating UL/CSA:(120 V AC) Single Phase 3/4 hp
(200 … 208 V AC) Three Phase 2 hp
(220 … 240 V AC) Three Phase 2 hp
(240 V AC) Single Phase 1-1/2 hp
(440 … 480 V AC) Three Phase 5 hp
(550 … 600 V AC) Three Phase 7-1/2 hp
Tightening Torque UL/CSA:Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 13 in·lb
Environmental
Ambient Air Temperature:Close to Contactor Fitted with Thermal O/L Relay -25 … 60 °C
Close to Contactor without Thermal O/L Relay -40 … 70 °C
Close to Contactor for Storage -60 … +80 °C
Climatic Withstand:Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:Without Derating 3000 m
Resistance to Vibrations acc. to IEC 60068-2-6:5 … 300 Hz 4 g closed position / 2 g open position
Resistance to Shock acc. to IEC 60068-2-27:Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
RoHS Status:Following EU Directive 2011/65/EU
Certificates and Declarations (Document Number)
ABS Certificate:ABS_20-2060694-PDA
BV Certificate:BV_2634H24898B0
CB Certificate:CB_SE-108879
CCC Certificate:CCC_2010010304445624
CQC Certificate:CQC2010010304445624
CQC2020010304298240
cUL Certificate:UL_20180227_E312527_7_1
Declaration of Conformity – CCC:2020980304001253
2020980304001082
Declaration of Conformity – CE:1SBD250000U1000
Declaration of Conformity – UKCA:1SBD250031U1000
EAC Certificate:EAC_RU_FRME77B03447
Environmental Information:1SBD250147E1000
1SBC100222M0201
GL Certificate:DNV-GL_TAE00001AF-3
GOST Certificate:GOST_POCCFR.ME77.B07175.pdf
Instructions and Manuals:1SBC101027M6801
KC Certificate:KC_HW02016-15004C
LR Certificate:LRS_1300087E1
RINA Certificate:RINA_ELE240318XG
RMRS Certificate:RMRS_1802705280
RoHS Information:1SBD250000U1000
UL Certificate:UL_20140305-E312527_7_1
UL Listing Card:E312527
Container Information
Package Level 1 Units:box 1 piece
Package Level 1 Width:87 mm
Package Level 1 Depth / Length:79 mm
Package Level 1 Height:47 mm
Package Level 1 Gross Weight:0.27 kg
Package Level 1 EAN:3471523110014
Package Level 2 Units:box 27 piece
Package Level 2 Width:250 mm
Package Level 2 Depth / Length:300 mm
Package Level 2 Height:315 mm
Package Level 2 Gross Weight:7.29 kg
Package Level 3 Units:1296 piece
Classifications
Object Classification Code:Q
ETIM 4:EC000066 – Magnet contactor, AC-switching
ETIM 5:EC000066 – Magnet contactor, AC-switching
ETIM 6:EC000066 – Power contactor, AC switching
ETIM 7:EC000066 – Power contactor, AC switching
ETIM 8:EC000066 – Power contactor, AC switching
eClass:V11.0 : 27371003
E-Number (Finland):3705800
E-Number (Sweden):3210016
Contact us to discover AF09-30-10-11. ICDCSPARES.COM offers new or overhauled original components, ready in stock to be shipped via DHL Express! Call us!
Check our Electromechanical section to discover more about ICDC catalog: a large selection of industrial spare parts including Fuses, Electric Motors, Switches and Relays.
Are you looking for industrial Relays? ICDC offers online a wide selection of Relays of the most important OEMs like EATON, ABB and DANFOSS, besides ABB.
ICDC, Your Industrial One Stop Shop for Components!