EATON – 22DILEM – Electronic Modules – ICDC-040324 – New
Main Category: Electronics | Sub-Category: Modules | Status: New Original Components
EATON Part Number: 22DILEM | ICDC Internal Part Number: ICDC-040324
22DILEM Description:
22DILEM – Auxiliary contact module, 4 pole, 2 N/O, 2 NC, Front fixing, Screw terminals, DILE(E)M
DELIVERY PROGRAM
Accessories
Auxiliary contact modules
Description
with interlocked opposing contacts
Switching elements according to EN 50012
Switching elements according to EN 50012 are to be preferred.
Version E combinations correspond to EN 50011 and are to be preferred.
Function
for standard applications
Number of poles
4 pole
Connection technique
Screw terminals
Rated operational current
AC-15
220 V 230 V 240 V [Ie] 4 A
AC-15
380 V 400 V 415 V [Ie] 2 A
Contacts
N/O = Normally open
2 N/O
N/C = Normally closed
2 NC
Mounting type
Front fixing
For use with
DILEM-10(-G)(…)
DILEM-4(-G)(…)
DILEEM-10(-G)(…)
DILEM12-10(-G)(…)
Instructions
Interlocked opposing contacts according to IEC/EN 60947-5-1 appendix L, inside the auxiliary contact modules, also for the integrated auxiliary contacts of the DILER, DILE(E)M
Auxiliary contacts used as mirror contacts according to IEC/EN 60947-4-1 Appendix F (not N/C late open)
TECHNICAL DATA
General
Standards
IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanical
AC operated [Operations] 10 x 106
Lifespan, mechanical
DC operated [Operations] 20 x 106
Component lifespan at Ue = 240 V
AC-15 [Operations] 0.2 x 106
Component lifespan at Ue = 240 V
DC
L/R = 50 ms: 2 contacts in series at Ie = 0.5 A [Operations] 0.15 x 106
Maximum operating frequency [Operations/h] 9000
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
Open
-25 – +50 °C
Ambient temperature
Enclosed
– 25 – 40 °C
Ambient temperature
Ambient temperature, storage
– 40 – 80 °C
Mounting position
Mounting position
As required, except vertical with terminals A1/A2 at the bottom
Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock, 10 ms
Basic unit with auxiliary contact module
N/O contact
10 g
Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock, 10 ms
Basic unit with auxiliary contact module
N/C contact
8 g
Degree of Protection
IP20
Protection against direct contact when actuated from front (EN 50274)
Finger and back-of-hand proof
Weight
0.04 kg
Terminal capacities
Screw terminals
Solid
1 x (0.75 – 2.5)
2 x (0.75 – 2.5) mm2
Terminal capacities
Screw terminals
Flexible with ferrule
1 x (0.75 – 1.5)
2 x (0.75 – 1.5) mm2
Terminal capacities
Screw terminals
Solid or stranded
Single 18 – 14/Double 18 – 14 AWG
Terminal capacities
Screw terminals
Terminal screw
M3.5
Terminal capacities
Screw terminals
Pozidriv screwdriver
2 Size
Terminal capacities
Screw terminals
Standard screwdriver
0.8 x 5.5
1 x 6 mm
Terminal capacities
Screw terminals
Max. tightening torque
1.2 Nm
Contacts
Interlocked opposing contacts within an auxiliary contact module (to IEC 60947-5-1 Annex L)
Yes
Rated impulse withstand voltage [Uimp] 6000 V AC
Overvoltage category/pollution degree
III/3
Rated insulation voltage [Ui] 690 V AC
Rated operational voltage [Ue] 600 V AC
Safe isolation to EN 61140
between coil and auxiliary contacts
300 V AC
Safe isolation to EN 61140
between the auxiliary contacts
300 V AC
Rated operational current
Conventional free air thermal current, 1 pole
Notes
At maximum permissible ambient air temperature.
Rated operational current
Conventional free air thermal current, 1 pole
Conv. thermal current [Ith] 10 A
Rated operational current
AC-15
220 V 230 V 240 V [Ie] 4 A
Rated operational current
AC-15
380 V 400 V 415 V [Ie] 2 A
Rated operational current
AC-15
500 V [Ie] 1.5 A
Rated operational current
DC current
Switch-on and switch-off conditions based on DC-13, time constant as specified.
Rated operational current
DC current
DC L/R ≦ 15 ms
Contacts in series:
1 [24 V] 2.5 A
Rated operational current
DC current
DC L/R ≦ 15 ms
Contacts in series:
2 [60 V] 2.5 A
Rated operational current
DC current
DC L/R ≦ 15 ms
Contacts in series:
3 [110 V] 1.5 A
Rated operational current
DC current
DC L/R ≦ 15 ms
Contacts in series:
3 [220 V] 0.5 A
Rated operational current
Control circuit reliability [Failure rate] <10-8, < one failure at 100 million operations
(at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA) λ
Short-circuit rating without welding
Maximum overcurrent protective device
220 V 230 V 240 V
4 PKZM0
Short-circuit rating without welding
Maximum overcurrent protective device
380 V 400 V 415 V
4 PKZM0
Short-circuit rating without welding
Short-circuit protection maximum fuse
500 V
6 A gG/gL
Short-circuit rating without welding
Short-circuit protection maximum fuse
500 V
10 A fast
Current heat loss at Ith
AC operated
1.5 W
Current heat loss at Ith
DC operated
1.5 W
Current heat loss at Ith
Current heat loss per auxiliary circuit at Ie (AC-15/230 V)
0.24 CO
Rating data for approved types
Auxiliary contacts
Pilot Duty
AC operated
A600
Auxiliary contacts
Pilot Duty
DC operated
P300
Auxiliary contacts
General Use
AC
600 V
Auxiliary contacts
General Use
AC
10 A
Auxiliary contacts
General Use
DC
250 V
Auxiliary contacts
General Use
DC
0.5 A
DESIGN VERIFICATION AS PER IEC/EN 61439
Technical data for design verification
Rated operational current for specified heat dissipation [In] 4 A
Heat dissipation per pole, current-dependent [Pvid] 0.24 W
Equipment heat dissipation, current-dependent [Pvid] 0 W
Static heat dissipation, non-current-dependent [Pvs] 0 W
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+50 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts
10.2.2 Corrosion resistance
Meets the product standard’s requirements.
10.2 Strength of materials and parts
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard’s requirements.
10.2 Strength of materials and parts
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard’s requirements.
10.2 Strength of materials and parts
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard’s requirements.
10.2 Strength of materials and parts
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard’s requirements.
10.2 Strength of materials and parts
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
10.2.7 Inscriptions
Meets the product standard’s requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard’s requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder’s responsibility.
10.8 Connections for external conductors
Is the panel builder’s responsibility.
10.9 Insulation properties
10.9.2 Power-frequency electric strength
Is the panel builder’s responsibility.
10.9 Insulation properties
10.9.3 Impulse withstand voltage
Is the panel builder’s responsibility.
10.9 Insulation properties
10.9.4 Testing of enclosures made of insulating material
Is the panel builder’s responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
TECHNICAL DATA ETIM 8.0
Low-voltage industrial components (EG000017) / Auxiliary contact block (EC000041)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Auxiliary switch block ([email protected] [AKN342013])
Number of contacts as change-over contact
0
Number of contacts as normally open contact
2
Number of contacts as normally closed contact
2
Number of fault-signal switches
0
Rated operation current Ie at AC-15, 230 V
4 A
Type of electric connection
Screw connection
Model
Top mounting
Mounting method
Front fastening
Lamp holder
None
APPROVALS
Product Standards
IEC/EN 60947-4-1
Contact us to discover 22DILEM. ICDCSPARES.COM offers new or overhauled original components, ready in stock to be shipped via DHL Express! Call us!
Check our Electronics section to discover more about ICDC catalog: a large selection of industrial spare parts including Fuses, Electric Motors, Switches and Modules.
Are you looking for industrial Modules? ICDC offers online a wide selection of Modules of the most important OEMs like EATON, ABB and DANFOSS, besides EATON.
ICDC, Your Industrial One Stop Shop for Components!