EATON – DILM1000-XHI11-SI – Electronic Modules – ICDC-040661 – New
Main Category: Electronics | Sub-Category: Modules | Status: New Original Components
EATON Part Number: DILM1000XHI11SI | ICDC Internal Part Number: ICDC-040661
DILM1000-XHI11-SI Description:
DILM1000-XHI11-SI – Auxiliary contact module, 2-pole, I ° = 10 A, 1 NO contact, 1 NC contact, Side mounting, Screw terminals, DILM40 – DILM225A, -SI
EATON 278425
SUPPLY PROGRAM
accessories
Auxiliary contact modules
Description
with forcibly guided contacts
Function
for standard applications
Poly
2-pole
Types of connection
Screw terminals
Rated operational current
Conventional thermal current 1 pole
per day
a 60 °C [I°]10 A
AC-15
220 V 230 V 240 V [I e ]4 A
AC-15
380 V 400 V 415 V [I e ]4 A
AC-15
380 V 400 V 500 V [I e ]4 A
Contact equipment
NA = norm. open
1 NO contact
NC = norm. Closed
1 NC contact
Mounting type
Side mounting
use with
DILM40 – DILM225A
DILMP63 – DILMP200
DILMF40 – DILMF95
Execution
Side auxiliary contacts
Note
Forcibly guided contacts, according to IEC / EN 60947-5-1 Annex L, inside the auxiliary contact modules Auxiliary
NC contact usable as mirror contact according to IEC / EN 60947-4-1 Annex F (non delayed NC contact)
TECHNICAL DATA
Generality
Compliance with standards
IEC/EN 60947, VDE 0660, UL, CSA
Lifespan of the appliance
with U e = 230 V, AC-15, 3 A [Operations]1.3 x 106
Suitability for climates
Humid heat, constant, according to IEC 60068-2-78
Humid heat, cyclic according to IEC 60068-2-30
Room temperature
per day
-25 – +60 °C
Room temperature
in custody
– 25 – 40 °C
Room temperature
Ambient storage temperature
-40 – 80 °C
Degree of protection
IP20
Protection against accidental contacts in case of frontal actuation (EN 50274)
Protection against finger contact and back of hand
Weight
0.041 kg
Connection sections
Screw terminals
Stiff
1 x (0,75-2,5)
2 x (0,75-2,5) mm2
Connection sections
Screw terminals
Flexible with ferrule
1 x (0,75-2,5)
2 x (0,75-2,5) mm2
Connection sections
Screw terminals
Single wire or stranded
18 – 14 AWG
Connection sections
Screw terminals
Pozidriv screwdriver
2 Size
Connection sections
Screw terminals
Flat-blade screwdriver
0.8 x 5.5
1 x 6 mm
Connection sections
Screw terminals
Max. Clamping force
1.2 Nm
Relay contacts
Forced guidance of the contact elements within an auxiliary contact module (in accordance with IEC 60947-5-1 Annex L)
Yup
NC contact (not delayed) suitable as mirror contact (in accordance with IEC / EN 60947-4-1 Appendix F)
DILM40 – DILM225A
Rated impulse withstand voltage [U imp ]6000 V AC
Overvoltage category / pollution degree
III/3
Rated insulation voltage [U i ]690 V AC
Rated operational voltage [U e ]500 V AC
Safe isolation according to EN 61140
between the coil and the contacts
440 V AC
Safe isolation according to EN 61140
between auxiliary contacts
440 V AC
Safe isolation according to EN 61140
between auxiliary contacts and main contacts
440 V AC
Rated operational current
Conventional thermal current 1 pole
a 60 °C [I°]10 A
Rated operational current
AC-15
220 V 230 V 240 V [I e ]4 A
Rated operational current
AC-15
380 V 400 V 415 V [I e ]4 A
Rated operational current
AC-15
500 V [I e ]1.5 A
Rated operational current
DC
Switch-on and switch-off conditions according to DC-13, constant L / R according to specification.
Rated operational current
DC
DC L/R ≦ 15 ms
Contacts in series:
1 [24 V]10 A
Rated operational current
DC
DC L/R ≦ 15 ms
Contacts in series:
1 [60V]6 A
Rated operational current
DC
DC L/R ≦ 15 ms
Contacts in series:
1 [110V]3 A
Rated operational current
DC
DC L/R ≦ 15 ms
Contacts in series:
1 [220V]1 A
Rated operational current
DC
DC-13 (6xP)
24 V [I e ]2 A
Rated operational current
DC
DC-13 (6xP)
60 V [I e ]1.5 A
Rated operational current
DC
DC-13 (6xP)
110 V [I e ]0.8 A
Rated operational current
DC
DC-13 (6xP)
220 V [I e ]0.3 A
Rated operational current
Safety against false maneuvers [Frequency of failure]<10 -8 ,
Short circuit resistance without welding
Short-circuit protection fuse max
500 V
16 A gG/gL
Rated conditional short-circuit current 500 V [I q ]1 kA
Ohmic loss at load with I th
Control in alternating current
0.69 Watts
Ohmic loss at load with I th
Direct current control
0.69 Watts
Ohmic loss at load with I th
Thermal dissipation for auxiliary circuit with I e (AC-15/230 V)
0.11 watts
Power data approved
Auxiliary contacts
Pilot Duty
Control in alternating current
A600
Auxiliary contacts
Pilot Duty
Direct current control
P300
Auxiliary contacts
General Use
AC
600 V
Auxiliary contacts
General Use
AC
15 A
Auxiliary contacts
General Use
DC
250 V
Auxiliary contacts
General Use
DC
1 A
DESIGN VERIFICATIONS ACCORDING TO IEC / EN 61439
Technical data for design checks
Rated operational current for dissipation data [I n ]4 A
Dissipation per pole, as a function of the current [P vid ]0.11 watts
Device dissipation, depending on the current [P vid ]0 W.
Static dissipation, independent of the current [P vs ]0 W.
Dissipation power [P ve ]0 W.
Ambient service temperature min.
-25 °C
Ambient service temperature max.
+60 °C
IEC / EN 61439 design verifications
10.2 Suitability of materials and components
10.2.2 Corrosion resistance
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.3.1 Resistance of the enclosure to heat
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.3.2 Resistance of insulating materials to normal heat levels
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.3.3 Resistance of insulating materials to extraordinary heat levels
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.4 Resistance to UV radiation
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.5 Lifting
Not relevant as the whole electrical panel needs to be evaluated.
10.2 Suitability of materials and components
10.2.6 Impact test
Not relevant as the whole electrical panel needs to be evaluated.
10.2 Suitability of materials and components
10.2.7 Lettering
The requirements of the product standard are met.
10.3 Degree of protection of the enclosures
Not relevant as the whole electrical panel needs to be evaluated.
10.4 Air and surface dispersion routes
The requirements of the product standard are met.
10.5 Protection against electric shock
Not relevant as the whole electrical panel needs to be evaluated.
10.6 Flush mounting of devices
Not relevant as the whole electrical panel needs to be evaluated.
10.7 Internal circuits and connections
It is the responsibility of the manufacturer of the electrical panel.
10.8 Connections for conductors introduced from outside
It is the responsibility of the manufacturer of the electrical panel.
10.9 Insulation characteristics
10.9.2 Dielectric strength at mains frequency
It is the responsibility of the manufacturer of the electrical panel.
10.9 Insulation characteristics
10.9.3 Impulse withstand voltage
It is the responsibility of the manufacturer of the electrical panel.
10.9 Insulation characteristics
10.9.4 Verification of enclosures in insulating material
It is the responsibility of the manufacturer of the electrical panel.
10.10 Heating
The superheat calculation is the responsibility of the electrical panel builder. Eaton provides equipment dissipation data.
10.11 Resistance to short circuit
It is the responsibility of the manufacturer of the electrical panel. Observe the default values of the equipment.
10.12 EMC
It is the responsibility of the manufacturer of the electrical panel. Observe the default values of the equipment.
10.13 Mechanical function
For the device, the requirements are met if the information in the installation instructions (IL) is observed.
TECHNICAL DATA ACCORDING TO ETIM 8.0
low voltage electrical appliances (EG000017) / Auxiliary contacts (EC000041)
Technique Of Ar., Electr., Energy, Tecn. Switchgear, Network & Mains Process / Low Voltage Switching Technology / Component For Low Voltage Switching Technology / Auxiliary Switch Block ([email protected] [AKN342013])
number of reversing contacts
0
number of closing contacts
1
number of rest contacts
1
number of signal switches
0
rated operating current Ie for AC-15, 230 V
6 A
making the electrical connection
screw connection
Typology
pluggable
Mounting type
side application
lamp holder
without
APPROVALS
Product Standards
IEC/EN 60947-4-1
Contact us to discover DILM1000-XHI11-SI. ICDCSPARES.COM offers new or overhauled original components, ready in stock to be shipped via DHL Express! Call us!
Check our Electronics section to discover more about ICDC catalog: a large selection of industrial spare parts including Fuses, Electric Motors, Switches and Modules.
Are you looking for industrial Modules? ICDC offers online a wide selection of Modules of the most important OEMs like EATON, ABB and DANFOSS, besides EATON.
ICDC, Your Industrial One Stop Shop for Components!