EUCHNER – CES-AZ-AES-01B, 104770 – Electrical Buttons – ICDC-040033 – New
Main Category: Electrical | Sub-Category: Buttons | Status: New Original Components
EUCHNER Part Number: 104770 | ICDC Internal Part Number: ICDC-040033
104770 Description:
CES-AZ-AES-01B (ORDER NO. 104770)
Evaluation unit CES-AZ-AES-01B (for 1 read head)
1 read head can be connected
2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
Start button and feedback loop can be connected
Unicode
Plug-in connection terminals
Category 4 / PL e according to EN ISO 13849-1
Unicode evaluation
Each actuator is highly coded (unicode). The evaluation unit detects only actuators that have been taught-in. Additional actuators can be taught-in.
Only the last actuator taught-in is detected.
New actuators are taught-in by fitting a jumper.
Guard lock monitoring
Evaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. You will find suitable read heads in the accessories.
Category according to EN ISO 13849-1
Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for:
Category 4/PL e according to EN ISO 13849-1
Each safety path is independently safe.
LED indicator
STATE
Status LED
DIA
Diagnostics LED
OUT
Safety output status
Additional connections
TST
Input for self-test
O1
Monitoring output (semiconductor)
DIA
Diagnostic output
Y1, Y2
Feedback loop
J
Teach-in input
S
Start button connection (monitoring of the falling edge)
Important: The plug-in connection terminals are not included and must be ordered separately.
Work area
Repeat accuracy R
according to EN 60947-5-2 max. 10 %
Controls and indicators
LED indicator
Safety contacts status
Status LED
Diagnostics LED
Electrical connection ratings
Connection cross-section
(plug-in screw/spring terminals) 0.25 … 2.5 mm²
Current consumption
(with relay energized) 150 mA
Fusing
external (operating voltage UB) 0.25 … 8 A
Operating voltage DC
UB 21 … 24 … 27 V DC regulated, residual ripple < 5%
EMC protection requirements according to EN 60947-5-3
Current via feedback loop 5 … 8 … 10 mA
Degree of contamination (external, according to EN 60947-1) 2
permissible resistance in feedback loop max. 600 Ω
Inputs: start button S, test input TST
Input voltage
HIGH 15 … UB V DC
LOW 0 … 2 V DC
Input current
HIGH 5 … 8 … 10 mA
Monitoring outputs: diagnostics DIA, door monitoring output O1
Output type Semiconductor output, p-switching, short circuit-proof
Output current max. 20 mA
Output voltage 0.8 x UB … UB V DC
Safety contacts 13/14, 23/24
Output type Relay contacts, floating
Fusing
external (safety circuit) according to EN 60269-1 6 AgG or 6 A circuit breaker (characteristic B or C)
rated conditional short-circuit current 100 A
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 4 kV
Discrepancy time
(between the operating points of both relays) max. 25 ms
Switching current
at switching voltage AC/DC 21 … 60 V 1 … 300 mA
at switching voltage AC/DC 5 … 30 V 10 … 6000 mA
at switching voltage AC 5 … 230 V 10 … 2000 mA
Utilization category
DC-13 24 V 3 A
AC-12 30 V 6 A
DC-12 60 V 0.3 A
AC-12 60 V 0.3 A
DC-12 30 V 6 A
AC-15 230 V 2 A
Switching load
according to c UL us Class 2 max. 30 V AC / Class 2 max. 60 V DC
Contact us to discover 104770. ICDCSPARES.COM offers new or overhauled original components, ready in stock to be shipped via DHL Express! Call us!
Check our Electrical section to discover more about ICDC catalog: a large selection of industrial spare parts including Fuses, Electric Motors, Switches and Buttons.