PHOENIX – 2900414 – Electromechanical Relays – ICDC-040159 – New
Main Category: Electromechanical | Sub-Category: Relays | Status: New Original Components
PHOENIX Part Number: 2900414 | ICDC Internal Part Number: ICDC-040159
2900414 Description:
Static relay for starting – ELR H5-IES-SC- 24DC / 500AC-2
2900414
Product type Three-phase static relays
Operation 100% ED
Number of phases 3
Type of static relay Reverse starter
Maximum power dissipated under nominal conditions 2.2 W
Switching frequency ≤ 2 Hz (depending on the load)
Maximum dissipated power 3.3 W
Minimum dissipated power 1.1 W
Type of assignment 1
Diet
Supply voltage of the dimensioning control circuit U S 24 V DC
Control supply voltage range 19.2 V DC … 30 V DC
Power supply, control, sizing current I S 40 mA
Protection circuit Overvoltage protection
Prot. Against polarity inversion
Features of insulation
Rated insulation voltage 500 V
Impulsive dimensioning voltage 6 kV
Overvoltage category III
Degree of pollution 2
Insulation characteristics between the control input voltage, the control supply voltage and the auxiliary circuit to the main circuit Safe separation (IEC 60947-1 / EN 50178) with operating voltage ≤ 300 V AC
Basic insulation (IEC 60947-1) with operating voltage ≤ 300 … 500 V AC
Safe separation (EN 50178) with operating voltage 300 … 500 V AC
Insulation characteristics between the control input voltage, the control supply voltage and the auxiliary circuit Safe separation (IEC 60947-1) with auxiliary circuit ≤ 300 V AC
Safe separation (EN 50178) with auxiliary circuit ≤ 300 V AC
Check
Entrance denomination Left / right control input
Rated working voltage U C 24 V DC
Activation voltage range 19.2 V DC … 30 V DC
Rated working current I C 5 mA (Input type 1)
Switching threshold 9.6 V (0signal)
19.2 V (Signal1)
Switching level <5 V DC (for EMERGENCY STOP)
Typical switch-off time <30 ms
Protection circuit Prot. Against polarity inversion
AC output
Tens. of exercise of dimensionam. U and 500 V AC
Operating voltage range 42 V AC … 550 V AC
Operating current I e 2.4 A (AC-51)
2.4 A (AC-53a)
Network frequency 50/60 Hz
Load current range 180 mA … 2.4 A (see derating)
Trip curve in accordance with IEC 60947-4-2 Class 10A
Cooling time 20 min. (for Auto Reset)
Leakage current 0 mA
Protection circuit Overvoltage protection
Alarm output
Note Response message: potential-free changeover contact, signal contact
Making contacts 1 diverter contact
Breaking capacity IEC 60947-5-1 3 A (230 V, AC15)
2 A (24 V, DC13)
Control circuit
Connection Screw connection
Stripping length 8 mm
Thread M3
Rigid conductor section 0.2 mm² … 2.5 mm²
Flexible conductor section 0.2 mm² … 2.5 mm²
Conductor cross section AWG 24 … 14
Tightening torque 0.5 Nm … 0.6 Nm
5 lb f -in. … 7 lb f -in.
Control circuit
Connection Screw connection
Stripping length 8 mm
Thread M3
Rigid conductor section 0.2 mm² … 2.5 mm²
Flexible conductor section 0.2 mm² … 2.5 mm²
Conductor cross section AWG 24 … 14
Length 22.5 mm
Height 107 mm
Depth 114 mm
Contact us to discover 2900414. ICDCSPARES.COM offers new or overhauled original components, ready in stock to be shipped via DHL Express! Call us!
Check our Electromechanical section to discover more about ICDC catalog: a large selection of industrial spare parts including Fuses, Electric Motors, Switches and Relays.
Are you looking for industrial Relays?
ICDC offers online a wide selection of Relays of the most important OEMs like EATON, ABB and DANFOSS, besides PHOENIX.ICDC, Your Industrial One Stop Shop for Components!