EATON – NZM1-XSM-L – Electrical Switches – ICDC-040897 – New
Main Category: Electrical | Sub-Category: Switches | Status: New Original Components
EATON Part Number: NZM1XSML | ICDC Internal Part Number: ICDC-040897
NZM1-XSM-L Description:
NZM1-XSM-L – Main switch mounting kit, left, frame size 1
EATON 266663
SUPPLY PROGRAM
Scope of supply
Handle for transmission and door lock with rotary element
Mounting bracket
Special short extension
External label for danger signal / identification plate in German / English
Danger symbol (black lightning bolt on a yellow background)
Assortment
Accessories
accessories
Kit for main switch for side mounting
Standard / Approval
UL/CSA, IEC
Size
NZM1
Description
Kit for use as a main switch
Function
For direct mounting of switch and handle in the side wall of the
Standard control cabinet, black / gray
Degree of protection
IP66
UL/CSA Type 4X, Type 12
Door lock
Lockable in position 0 on the handle
which can be changed to be padlocked in position I
There is a fixed minimum distance between the side panels of the electrical panel and the automatic power switch through the mounting bracket.
Extensions that cannot be used.
Design information
External label for danger signaling / insertable identification label
For greater protection against accidental contact on the power supply side, order protection against contacts IP2X.
drive
Command left
use with
NZM1 (-4)
PN1 (-4), N (S) 1 (-4)
Note
Arrangement of additional terminals with lateral actuation with fixing bracket
NZM1-XS(R)M-…, NZM2-XS(R)M-…
Additional terminals K25, K50, K95, K150 093827
DESIGN VERIFICATIONS ACCORDING TO IEC / EN 61439
IEC / EN 61439 design verifications
10.2 Suitability of materials and components
10.2.2 Corrosion resistance
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.3.1 Resistance of the enclosure to heat
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.3.2 Resistance of insulating materials to normal heat levels
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.3.3 Resistance of insulating materials to extraordinary heat levels
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.4 Resistance to UV radiation
The requirements of the product standard are met.
10.2 Suitability of materials and components
10.2.5 Lifting
Not relevant as the whole electrical panel needs to be evaluated.
10.2 Suitability of materials and components
10.2.6 Impact test
Not relevant as the whole electrical panel needs to be evaluated.
10.2 Suitability of materials and components
10.2.7 Lettering
The requirements of the product standard are met.
10.3 Degree of protection of the enclosures
Not relevant as the whole electrical panel needs to be evaluated.
10.4 Air and surface dispersion routes
The requirements of the product standard are met.
10.5 Protection against electric shock
Not relevant as the whole electrical panel needs to be evaluated.
10.6 Flush mounting of devices
Not relevant as the whole electrical panel needs to be evaluated.
10.7 Internal circuits and connections
It is the responsibility of the manufacturer of the electrical panel.
10.8 Connections for conductors introduced from outside
It is the responsibility of the manufacturer of the electrical panel.
10.9 Insulation characteristics
10.9.2 Dielectric strength at mains frequency
It is the responsibility of the manufacturer of the electrical panel.
10.9 Insulation characteristics
10.9.3 Impulse withstand voltage
It is the responsibility of the manufacturer of the electrical panel.
10.9 Insulation characteristics
10.9.4 Verification of enclosures in insulating material
It is the responsibility of the manufacturer of the electrical panel.
10.10 Heating
The superheat calculation is the responsibility of the electrical panel builder. Eaton provides equipment dissipation data.
10.11 Resistance to short circuit
It is the responsibility of the manufacturer of the electrical panel. Observe the default values of the equipment.
10.12 EMC
It is the responsibility of the manufacturer of the electrical panel. Observe the default values of the equipment.
10.13 Mechanical function
For the device, the requirements are met if the information in the installation instructions (IL) is observed.
TECHNICAL DATA ACCORDING TO ETIM 8.0
low voltage electrical appliances (EG000017) / Handle for protection switch (EC000229)
Technique Of Ar., Electr., Energy, Tecn. For Comm., Network And Pipeline Processes / Low Voltage Switching Technology / Power Switches (Ns, <1 Hp) / Handle for Control Units ([email protected] [AKF012014 ])
with restart interlock
no
With key lock
no
lock with padlock
Yes
color
black
suitable for emergency stop
no
with axis
Yes
suitable for circuit breaker
Yes
suitable for load disconnector
Yes
type of protection (NEMA)
4X, 12
APPROVALS
Product Standards
UL489
Contact us to discover NZM1-XSM-L. ICDCSPARES.COM offers new or overhauled original components, ready in stock to be shipped via DHL Express! Call us!
Check our Electrical section to discover more about ICDC catalog: a large selection of industrial spare parts including Fuses, Electric Motors, Switches and Switches.
Are you looking for industrial Switches?
ICDC offers online a wide selection of Switches of the most important OEMs like EATON, ABB and DANFOSS, besides EATON.ICDC, Your Industrial One Stop Shop for Components!