NZMB1-A63-NA Description:
DELIVERY PROGRAM
Product range
Circuit-breaker
Protective function
System and cable protection
Standard/Approval
IEC, UL
Release system
Thermomagnetic release
Installation type
Fixed
Description
Adjustable overload releases Ir
Frame size
NZM1
Number of poles
3 pole
Standard equipment
Box terminal
Switching capacity
SCCR 480Y/277 V 60 Hz [Icu] 25 kA
Rated current = rated uninterrupted current [In = Iu ] Rated current = rated uninterrupted current [In = Iu] 63 A
Setting range
Overload trip
[Ir ] 50 – 63 A
Short-circuit releases [Irm ] Non-delayed [Ii = In x …] 6 – 10
TECHNICAL DATA
General
Standards
IEC/EN 60947
Protection against direct contact
Finger and back of hand proof to VDE 0106 Part 100
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
Ambient temperature, storage
– 40 – + 70 °C
Ambient temperature
Operation
-25 – +70 °C
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27
20 (half-sinusoidal shock 20 ms) g
Safe isolation to EN 61140
Between auxiliary contacts and main contacts
500 V AC
Safe isolation to EN 61140
between the auxiliary contacts
300 V AC
Mounting position
Mounting position
Vertical and 90° in all directions
With XFI earth-fault release:
– NZM1, N1, NZM2, N2: vertical and 90° in all directions
with plug-in unit
– NZM1, N1, NZM2, N2: vertical, 90° right/left
with withdrawable unit:
– NZM3, N3: vertical, 90° right/left
– NZM4, N4: vertical
with remote operator:
– NZM2, N(S)2, NZM3, N(S)3, NZM4, N(S)4: vertical and 90° in all directions
Direction of incoming supply
as required
Degree of protection
Device
In the operating controls area: IP20 (basic degree of protection)
Degree of protection
Enclosures
With insulating surround: IP40
With door coupling rotary handle: IP66
Degree of protection
Terminations
Tunnel terminal: IP10
Phase isolator and strip terminal: IP00
Other technical data (sheet catalogue)
Weight
Temperature dependency, Derating
Effective power loss
Circuit-breakers
Rated surge voltage invariability [Uimp ] Main contacts
6000 V
Rated surge voltage invariability [Uimp ] Auxiliary contacts
6000 V
Rated operational voltage [Ue] 440 V AC
Overvoltage category/pollution degree
III/3
Rated insulation voltage [Ui ] 690 V
Use in unearthed supply systems
≦ 440 V
Switching capacity
Rated short-circuit making capacity [Icm ] 240 V [Icm ] 63 kA
Rated short-circuit making capacity [Icm ] 400/415 V [Icm ] 53 kA
Rated short-circuit making capacity [Icm ] 440 V 50/60 Hz [Icm ] 53 kA
Rated short-circuit breaking capacity Icn [Icn ] Icu to IEC/EN 60947 test cycle O-t-CO [Icu] 240 V 50/60 Hz [Icu ] 30 kA
Rated short-circuit breaking capacity Icn [Icn ] Icu to IEC/EN 60947 test cycle O-t-CO [Icu] 400/415 V 50/60 Hz [Icu ] 25 kA
Rated short-circuit breaking capacity Icn [Icn ] Icu to IEC/EN 60947 test cycle O-t-CO [Icu] 440 V 50/60 Hz [Icu ] 25 kA
Rated short-circuit breaking capacity Icn [Icn ] Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics] 240 V 50/60 Hz [Ics ] 30 kA
Rated short-circuit breaking capacity Icn [Icn ] Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics] 400/415 V 50/60 Hz [Ics ] 25 kA
Rated short-circuit breaking capacity Icn [Icn ] Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics] 440 V 50/60 Hz [Ics ] 18.5 kA
Rated short-circuit breaking capacity Icn [Icn ] Maximum low-voltage h.b.c. fuse
200 A gG/gL
Rated short-circuit breaking capacity Icn [Icn ] Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit-breaker.
Technical data that diverge from products for the IEC market
Switching capacity of NA switches (UL489, CSA 22.2 No. 5.1)
Short-circuit current rating SCCR
SCCR 240 V 60 Hz [Icu] 35 kA
Technical data that diverge from products for the IEC market
Switching capacity of NA switches (UL489, CSA 22.2 No. 5.1)
Short-circuit current rating SCCR
SCCR 480Y/277 V 60 Hz [Icu] 25 kA
Utilization category to IEC/EN 60947-2
A
Lifespan, mechanical(of which max. 50 % trip by shunt/undervoltage release) [Operations] 20000
Lifespan, electrical
AC-1
400 V 50/60 Hz [Operations] 7500
Lifespan, electrical
Max. operating frequency
120 Ops/h
Total break time at short-circuit
< 10 ms
Terminal capacity
Standard equipment
Box terminal
Round copper conductor
Box terminal
Solid
1 x (12 … 6) mm2
Round copper conductor
Box terminal
Stranded
1 x (25 – 70)
2 x 25 mm2
Round copper conductor
Tunnel terminal
Solid
1 x (16 – 95) mm2
Round copper conductor
Tunnel terminal
Stranded
Stranded
1 x (4 … 3/0) mm2
Round copper conductor
Bolt terminal and rear-side connection
Direct on the switch
Solid
1 x (12 … 6)
2 x (9 … 6) mm2
Round copper conductor
Bolt terminal and rear-side connection
Direct on the switch
Stranded
1 x (4 … 2/0) mm2
Al conductors, Cu cable
Tunnel terminal
Solid
1 x 16 mm2
Cu strip (number of segments x width x segment thickness)
Box terminal [min.] 2 x 9 x 0.8 mm
Cu strip (number of segments x width x segment thickness)
Box terminal [max.] 9 x 9 x 0.8 mm
Copper busbar (width x thickness) [mm] Bolt terminal and rear-side connection
Screw connection
M8
Copper busbar (width x thickness) [mm] Bolt terminal and rear-side connection
Direct on the switch [min.] 12 x 5 mm
Copper busbar (width x thickness) [mm] Bolt terminal and rear-side connection
Direct on the switch [max.] 16 x 5 mm
Control cables
1 x (18 … 14)
2 x (18 … 16) mm2
DESIGN VERIFICATION AS PER IEC/EN 61439
Technical data for design verification
Rated operational current for specified heat dissipation [In] 63 A
Equipment heat dissipation, current-dependent [Pvid] 14.17 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+70 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts
10.2.2 Corrosion resistance
Meets the product standard’s requirements.
10.2 Strength of materials and parts
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard’s requirements.
10.2 Strength of materials and parts
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard’s requirements.
10.2 Strength of materials and parts
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard’s requirements.
10.2 Strength of materials and parts
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard’s requirements.
10.2 Strength of materials and parts
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
10.2.7 Inscriptions
Meets the product standard’s requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard’s requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder’s responsibility.
10.8 Connections for external conductors
Is the panel builder’s responsibility.
10.9 Insulation properties
10.9.2 Power-frequency electric strength
Is the panel builder’s responsibility.
10.9 Insulation properties
10.9.3 Impulse withstand voltage
Is the panel builder’s responsibility.
10.9 Insulation properties
10.9.4 Testing of enclosures made of insulating material
Is the panel builder’s responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
TECHNICAL DATA ETIM 8.0
Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation protection (EC000228)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection ([email protected] [AJZ716013])
Rated permanent current Iu
63 A
Rated voltage
440 – 440 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
25 kA
Overload release current setting
50 – 63 A
Adjustment range short-term delayed short-circuit release
0 – 0 A
Adjustment range undelayed short-circuit release
380 – 630 A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Frame clamp
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
Yes
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
No
With integrated under voltage release
No
Number of poles
3
Position of connection for main current circuit
Front side
Type of control element
Rocker lever
Complete device with protection unit
Yes
Motor drive integrated
No
Motor drive optional
No
Degree of protection (IP)
IP20
APPROVALS
Product Standards
UL 489