EUCHNER – CTP-L1-AP-U-HA-AZ-SA-124225 – Electromechanical Circuit Breakers | ICDC-041505
Main Category: Electromechanical | Sub-Category: Circuit Breakers | Status: New Components in Original Box
Manufacturer: EUCHNER | Part Number: CTPL1APUHAAZSA124225 | ICDC Part Number: ICDC-041505
Lead Time: 2 Days to Shipping + DHL Express Transit Time
CTP-L1-AP-U-HA-AZ-SA-124225 Description:
CES-AZ-AES-01B (ORDER NO. 104770)
Evaluation unit CES-AZ-AES-01B (for 1 read head)
1 read head can be connected
2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
Start button and feedback loop can be connected
Unicode
Plug-in connection terminals
Category 4 / PL e according to EN ISO 13849-1
Unicode evaluation
Each actuator is highly coded (unicode). The evaluation unit detects only actuators that have been taught-in. Additional actuators can be taught-in.
Only the last actuator taught-in is detected.
New actuators are taught-in by fitting a jumper.
Guard lock monitoring
Evaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. You will find suitable read heads in the accessories.
Category according to EN ISO 13849-1
Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for:
Category 4/PL e according to EN ISO 13849-1
Each safety path is independently safe.
LED indicator
STATE
Status LED
DIA
Diagnostics LED
OUT
Safety output status
Additional connections
TST
Input for self-test
O1
Monitoring output (semiconductor)
DIA
Diagnostic output
Y1, Y2
Feedback loop
J
Teach-in input
S
Start button connection (monitoring of the falling edge)
Important: The plug-in connection terminals are not included and must be ordered separately.
Work area
Repeat accuracy R
according to EN 60947-5-2 max. 10 %
Controls and indicators
LED indicator
Safety contacts status
Status LED
Diagnostics LED
Electrical connection ratings
Connection cross-section
(plug-in screw/spring terminals) 0.25 … 2.5 mm²
Current consumption
(with relay energized) 150 mA
Fusing
external (operating voltage UB) 0.25 … 8 A
Operating voltage DC
UB 21 … 24 … 27 V DC regulated, residual ripple < 5%
EMC protection requirements according to EN 60947-5-3
Current via feedback loop 5 ... 8 ... 10 mA
Degree of contamination (external, according to EN 60947-1) 2
permissible resistance in feedback loop max. 600 Ω
Inputs: start button S, test input TST
Input voltage
HIGH 15 ... UB V DC
LOW 0 ... 2 V DC
Input current
HIGH 5 ... 8 ... 10 mA
Monitoring outputs: diagnostics DIA, door monitoring output O1
Output type Semiconductor output, p-switching, short circuit-proof
Output current max. 20 mA
Output voltage 0.8 x UB ... UB V DC
Safety contacts 13/14, 23/24
Output type Relay contacts, floating
Fusing
external (safety circuit) according to EN 60269-1 6 AgG or 6 A circuit breaker (characteristic B or C)
rated conditional short-circuit current 100 A
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 4 kV
Discrepancy time
(between the operating points of both relays) max. 25 ms
Switching current
at switching voltage AC/DC 21 ... 60 V 1 ... 300 mA
at switching voltage AC/DC 5 ... 30 V 10 ... 6000 mA
at switching voltage AC 5 ... 230 V 10 ... 2000 mA
Utilization category
DC-13 24 V 3 A
AC-12 30 V 6 A
DC-12 60 V 0.3 A
AC-12 60 V 0.3 A
DC-12 30 V 6 A
AC-15 230 V 2 A
Switching load
according to c UL us Class 2 max. 30 V AC / Class 2 max. 60 V DC; 120 V AC 3 A / 240 V AC 1.5 A
Mechanical values and environment
Number of read heads 1 read head can be connected
Connection plug-in connection terminals, coded
Degree of protection IP20
Ready delay 10 ... 12 s
Material
Housing Plastic PA6.6
Switching frequency max. 0.25 Hz
Reaction time
Start button response delay (for Manual start operating mode) 200 ... 300 ms
after change in the actuation status max. 210 ms
Start button actuating duration (for Manual Start operating mode) min. 250 ms
Atmospheric humidity
not condensing max. 80 % rH
Mounting distance
laterally to the neighboring device min. 10 mm
Mounting type Mounting rail 35 mm according to DIN EN 60715 TH35
Ambient temperature
at UB = 24V DC -20 ... +55 °C
Dwell time min. 3 s
Safety contacts 13/14, 23/24
Number of safety contacts 2 Relay with internally monitored contacts
Mechanical life
Operating cycles (relay) 10 x 10⁶
Reliability values acc. to EN ISO 13849-1
Diagnostic Coverage (DC) 99 %
Number of switching cycles
≤ 0.1 A at 24 V DC max. 760000 1/y
≤ 3 A at 24 V DC max. 34600 1/y
≤ 1 A at 24 V DC max. 153000 1/y
Mission time 20 y
Monitoring of the guard position
Category 4
Performance Level PL e
PFHD 1.9 x 10-8
Miscellaneous
The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measure.
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V
Mounting distance
neighboring read heads min. 50 mm
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BBA-071840, CES-A-BCA
Actuator distance s
Minimum distance for side approach direction min. 3 mm
Assured operating distances sao
with center offset m=0 min. 10 mm
Assured release distance sar max. 26 mm
Operating distance
with center offset m=0 15 mm
Switching hysteresis 0.5 ... 2 mm
In combination with read head CES-A-LMN-SC
Mounting distance
neighboring read heads min. 20 mm
In combination with read head CES-A-LMN-SC and actuator CES-A-BDA-20
Assured operating distances sao
with center offset m=0 min. 6 mm
Assured release distance sar
with center offset m=0 max. 26 mm
Operating distance
with center offset m=0 9 mm A distance of s = 4 mm must be maintained for a side approach direction.
Switching hysteresis
with center offset m=0 1 ... 1.8 mm
In combination with read head CES-A-LMN-SC and actuator CES-A-BDA-18-156935
Actuator distance s
Minimum distance for side approach direction min. 3 mm
Assured operating distances sao
with center offset m=0 min. 6 mm
Assured release distance sar max. 21 mm
Operating distance
with center offset m=0 9 mm
Switching hysteresis
with center offset m=0 0.5 ... 1 mm
In combination with read head CES-A-LSP-05V-104966, CES-A-LSP-10V-104967, CES-A-LSP-SB-104969, CES-A-LSP-15V-106271 and actuator CES-A-BSP-104970
Assured operating distances sao
with center offset m=0 min. 10 mm
Assured release distance sar max. 45 mm
Operating distance
with center offset m=0 20 mm
Switching hysteresis 1 ... 4 mm
In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294
Mounting distance
neighboring read heads min. 160 mm
In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294 and actuator CES-A-BDN-06-104730
Assured operating distances sao
in z direction (with center offset x,y=0), in y direction (with center offset x,z=0) min. 14 mm
Assured release distance sar
in y direction max. 100 mm
in x or z direction max. 50 mm
Operating distance
in z direction (with center offset x,y=0), in y direction (with center offset x,z=0) 19 mm
Switching hysteresis 4 mm
In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294 and actuator CES-A-BBN-106600
Assured operating distances sao
in z direction (with center offset x,y=0), in y direction (with center offset x,z=0) min. 10 mm
Assured release distance sar
in x or z direction max. 50 mm
in y direction max. 100 mm
Operating distance
in z direction (with center offset x,y=0), in y direction (with center offset x,z=0) 15 mm
Switching hysteresis 1 ... 4 mm
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-20
Actuator distance s
Minimum distance for side approach direction min. 4 mm
Assured operating distances sao
with center offset m=0 min. 11 mm
Assured release distance sar max. 33 mm
Operating distance
with center offset m=0 16 mm
Switching hysteresis 0.5 ... 2 mm
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-18-156935
Actuator distance s
Minimum distance for side approach direction min. 5 mm
Assured operating distances sao
with center offset m=0 min. 10 mm
Assured release distance sar max. 32 mm
Operating distance
with center offset m=0 16 mm
Switching hysteresis
with center offset m=0 0.5 ... 1.4 mm
In combination with read head CES-A-LMN-SC and actuator CES-A-BBA-071840
Assured operating distances sao
with center offset m=0 min. 5 mm
Assured release distance sar
with center offset m=0 max. 25 mm
Operating distance
with center offset m=0 8 mm A distance of s = 3 mm must be maintained for a side approach direction.
Switching hysteresis
with center offset m=0 1 ... 1.8 mm
In combination with read head CES-A-LMN-SC and actuator CES-A-BMB
Actuator distance s
Minimum distance min. 1.2 mm
Assured operating distances sao
with center offset m=0 min. 3.5 mm
Assured release distance sar max. 10 mm
Operating distance
with center offset m=0 5 mm
Switching hysteresis 0.1 ... 0.3 mm
In combination with read head CES-A-LQA-SC
Mounting distance
neighboring read heads min. 80 mm
In combination with read head CES-A-LQA-SC and actuator CES-A-BBA-071840, CES-A-BCA
Assured operating distances sao
for vertical approach direction (center offset m=0) min. 10 mm
for side approach direction (distance in x direction 8 mm) min. +/- 18 mm
Assured release distance sar max. 47 mm
Operating distance
for vertical approach direction (center offset m=0) 15 mm
for side approach direction (distance in x direction 8 mm) +/- 22 mm
Switching hysteresis
for side approach direction (distance in x direction 8 mm) 1 ... 1.8 mm
for vertical approach direction (center offset m=0) 2 ... 3 mm
In combination with read head CES-A-LQA-SC and actuator CES-A-BQA
Assured operating distances sao
for side approach direction (distance in x direction 10 mm) min. +/- 24 mm
for vertical approach direction (center offset m=0) min. 16 mm
Assured release distance sar max. 60 mm
Operating distance
for vertical approach direction (center offset m=0) 23 mm
for side approach direction (distance in x direction 10 mm) +/- 28 mm
Switching hysteresis
for vertical approach direction (center offset m=0) 2 ... 3 mm
for side approach direction (distance in x direction 10 mm) 1 ... 1.3 mm
Contact us to discover more about the Circuit Breakers by EUCHNER code CTP-L1-AP-U-HA-AZ-SA-124225
Are you looking for EUCHNER industrial components?
ICDCSPARES.COM offers new and overhauled original components, ready in stock to be shipped via DHL Express! Call us!
Check our Circuit Breakers section to discover more about ICDC catalog: a wide selection of industrial spare parts, including Compressors, Flow Control Valves, UPS and Rotary Joints, besides Circuit Breakers. ICDC offers online a wide selection of Electromechanical industrial components of the most important OEMs like EUGEN SEITZ, BECKHOFF, SKF, COPELAND and ALFA LAVAL beyond EUCHNER.